نتایج جستجو برای: multileaf collimator

تعداد نتایج: 3034  

Journal: :Physics in medicine and biology 2005
Thomas Kalinowski

Multileaf collimators (MLCs) are the prevailing tool for the realization of radiation fields in intensity modulated radiation therapy (IMRT). One step in the treatment planning is to determine a set of leaf positions realizing a certain intensity modulated radiation field. In this paper we suggest two extensions in the use of the MLC that lead to considerable savings in terms of monitor units, ...

2010
Anees Dhabaan Eric Elder Eduard Schreibmann Ian Crocker Walter J. Curran Nelson M. Oyesiku Hui‐Kuo Shu Tim Fox

The objective was to evaluate the performance of a high-definition multileaf collimator (MLC) of 2.5 mm leaf width (MLC2.5) and compare to standard 5 mm leaf width MLC (MLC5) for the treatment of intracranial lesions using dynamic conformal arcs (DCA) technique with a dedicated radiosurgery linear accelerator. Simulated cases of spherical targets were created to study solely the effect of targe...

2018
Ehab M. Attalla Ismail Eldesoky

Article type: Original Article Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IM...

2014
Abdolreza Hashemian Mohammad Taghi Bahreyni Toossi Shahrokh Nasseri

Multileaf collimator (MLC) is among the radiation field shaping systems used for conformal radiotherapy and intensity modulation radiation therapy techniques. The MLC system that has been designed and fabricated in this study includes 52 leaves, 52 stepper motors, 2 DC motors, 16 programmable logic controllers (PLCs) and one human machine interface (HMI). This system can be mounted on conventio...

2010
Ahmed A. Eldib Mohamed I. ElGohary Jiajin Fan Lihui Jin Jinsheng Li C‐M Charlie Ma Nader A. Elsherbini

Modulated electron radiation therapy (MERT) has been proven as an effective way to deliver conformal dose distributions to shallow tumors while sparing distal critical structures and surrounding normal tissues. It had been shown that a dedicated electron multileaf collimator (eMLC) is necessary to reach the full potential of MERT. In this study, a manually-driven eMLC for MERT was investigated....

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید