نتایج جستجو برای: neutron

تعداد نتایج: 46140  

2012
H. Tomita

An epithermal neutron camera based on energy-filtered imaging with gas electron multipliers was developed. Epithermal neutron imaging is achievable without time-of-flight detection of neutrons by using a resonance filter and a thermal neutron absorber. This technique is applicable to compact accelerator-based neutron sources. Blurring of epithermal neutron images caused by neutron scattering in...

2008
N. Tsujimura T. Yoshida C. Takada T. Nunomiya K. Aoyama

Recently, several electronic personal dosemeters (EPDs) capable of measuring neutron dose equivalents were developed and have appeared on the market. The authors initiated the present study to assess performance of neutron EPDs. The EPD selected for this study was NRY21, manufactured by Fuji Electric Systems Co., Ltd. This dosemeter uses two silicon semiconductor detectors (a fast neutron senso...

Journal: :Physics Letters B 2006

Journal: :Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment 2015
Yanping Xu Gerhard Randers-Pehrson Stephen A Marino Guy Garty Andrew Harken David J Brenner

A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significan...

Journal: :Organic & biomolecular chemistry 2012
Fabrizio Fabris Ottorino De Lucchi Ilaria Nardini Marco Crisma Andrea Mazzanti Sax A Mason Marie-Hélène Lemée-Cailleau Francesca A Scaramuzzo Cristiano Zonta

(+)-syn-Benzotriborneol forms stable complexes with one molecule of water. This is due to the ability of the host to form three hydrogen bonds with water, to act simultaneously as a hydrogen-bond acceptor and donor, and to a perfect geometrical match between the pair. We report experimental (X-ray and neutron diffraction, VT NMR, DSC, TGA) and stereochemical studies carried out to elucidate and...

2007
G. Apostolopoulos

Neutron scattering techniques, such as neutron diffraction, small angle neutron scattering and neutron reflectometry consist very powerful tools for the non-destructive study of materials. At the Greek Research Reactor, GRR-1, a number of neutron scattering methods are employed and developed. In the present contribution, a short description of the methods and facilities is given, as well as som...

ژورنال: سنجش و ایمنی پرتو 2016

An epithermal neutron beam has been designed for Boron neutron Capture Therapy (BNCT) at the thermal column of Tehran Research Reactor (TRR) recently. In this paper the whole body effective dose, as well as the equivalent doses of several organs have been calculated in this facility using MCNPX Monte Carlo code. The effective dose has been calculated by using the absorbed doses determined for e...

سیوف‌جهرمی, سیدسعید, مسعودی, سیدفرهاد,

In the past decades, neutron reflectometry have flourished as an applicable method to the study of thin films. As an example, the type and thickness of an unknown thin film which is mounted on top of a magnetic substratum could be determined by measuring the intensity and polarization of the reflected neutrons from the sample. Neutron reflectometry is based on solving the one dimentional schröd...

2016
Hang Li Yang Wu Heyong Huo Bin Tang

Neutron phase contrast imaging is a recently developmental technique which is based not only on the amplitude like in the projection imaging but also on the contribution of phase alteration of the neutron beam. With the additional contrast from the difference of neutron refraction index in the sample which mainly leads to edge enhancement, phase contrast imaging can show more details about the ...

2016
Pham Ngoc Son Vuong Huu Tan

INTRODUCTION Several compositions of neutron filters have been installed at the channel No. 4 of the Dalat research reactor to produce quasi-monoenergetic neutron beams. However, this neutron facility has been proposed to enhance the quality of the experimental instruments, and to characterize the neutron spectrum parameters for new filtered neutron beams of 2 keV, 24 keV, 59 keV and 133 keV. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید