نتایج جستجو برای: oximetry

تعداد نتایج: 3912  

Journal: :Hong Kong medical journal = Xianggang yi xue za zhi 2000
T W Mak C W Kam J P Lai C M Tang

The management of carbon monoxide poisoning requires an accurate assessment of the extent of blood oxygenation. Measuring the fractional oxyhaemoglobin content by using co-oximetry gives a true picture of the oxygen-carrying capacity of blood in the presence of carboxyhaemoglobin. The use of readings from pulse oximetry or a standard blood gas analyser is insufficient and can be misleading. We ...

Journal: :Chest 2015
Teruya Asahina Katsuyuki Miyasaka

We read with great interest the article by Aldrich et al 1 in this issue of CHEST (see page 1484 ). In 2003, we reported our trial of measuring noninvasive arterial saturation during a pulseless situation (cardiopulmonary bypass [CPB]) by inducing a simulated pulse. 2 We were interested in fi nding a way to obtain pulse oximeter function during CPB at the time because we had experienced a morta...

2010
JOHANNES H. VAN OOSTROM BRIAN FUEHRLEIN RICHARD J. MELKER

Stokes (1) reported that the colored substance in blood carries oxygen. This was followed by Hoppe-Seyler (2), who first crystallized this substance and coined the term hemoglobin. Additionally, it was shown that the pattern of light absorption changes when shaken with air (2). Hertzman (3) described using photoelectric plethysmography of fingers and toes as a dynamic analysis of the peripheral...

Journal: :European journal of obstetrics, gynecology, and reproductive biology 1997
M A Hanson J G Nijhuis

Fetal well-being depends on the level of oxygenation in vital organs such as the heart and brain. In this review, we discuss the physiological parameters which underlie the use of pulse oximetry to evaluate fetal conditions intrapartum. Whilst the measurement of haemoglobin oxygen saturation (SaO2) depends on partial pressure of oxygen (PO2), the relation is alinear, is relatively insensitive t...

Journal: :trauma monthly 0
hossein alimohammadi department of emergency medicine, imam hosein hospital, shahid beheshti university of medical sciences, tehran, ir iran alireza baratloo department of emergency medicine, shohadaye tajrish hospital, shahid beheshti university of medical sciences, tehran, ir iran; department of emergency medicine, shohadaye tajrish hospital, shahid beheshti university of medical sciences, tehran, ir iran. tel.: +98-9122884364, fax: +98-2122721155 ali abdalvand department of family medicine, university of alberta, edmonton, canada alaleh rouhipour department of pediatrics, valeeasr hospital, ghazvin university of medical sciences, abyek, ir iran saeed safari department of emergency medicine, shohadaye tajrish hospital, shahid beheshti university of medical sciences, tehran, ir iran

background pain management with the use of sedatives and analgesics has several advantages and few complications or side effects. objectives in this study, we planned to evaluate the effects of pain control on oxygen saturation independent of other factors, such previous cardio-pulmonary conditions or respiratory rate. patients and methods sixty-seven adult patients with direct trauma to extrem...

Journal: :Heart & lung : the journal of critical care 1998
L A Jensen J E Onyskiw N G Prasad

OBJECTIVE The purposes of the study were to: (1) describe the aggregate strength of the relationship of arterial oxygen saturation as measured by pulse oximetry with the standard of arterial blood gas analysis as measured by co-oximetry, (2) examine how various factors affect this relationship, and (3) describe an aggregate estimate of the bias and precision between oxygen saturation as measure...

Journal: :Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas 2007
C Ribeiro de Andrade M C Duarte P Camargos

Few studies are available concerning correlations between pulse oximetry and peak expiratory flow in children and adolescents with acute asthma. Although the Global Initiative for Asthma states that measurements of lung function and oximetry are critical for the assessment of patients, it is not clear if both methods should necessarily be included in their evaluation. Since there is a significa...

Journal: :Chest 1996
J P McGovern S A Sasse D W Stansbury L A Causing R W Light

INTRODUCTION Measurement of oxygen saturation by pulse oximetry (SpO2) is frequently performed during exercise testing of patients with COPD to monitor for hypoxemia. The purpose of this study was to assess the accuracy and precision of pulse oximetry during exercise. We hypothesized that the SpO2 would more closely reflect oxygen saturation as measured by co-oximetry (SaO2) when it was correct...

2014
Daniel Redford Samata Paidy Faisal Kashif

BACKGROUND Traditional patient monitoring may not detect cerebral tissue hypoxia, and typical interventions may not improve tissue oxygenation. Therefore, monitoring cerebral tissue oxygen status with regional oximetry is being increasingly used by anesthesiologists and perfusionists during surgery. In this study, we evaluated absolute and trend accuracy of a new regional oximetry technology in...

Journal: :Experimental eye research 2013
Sunni R Patel Chris Hudson John G Flanagan Rebekka Heitmar

To assess the impact of light scatter, similar to that introduced by cataract on retinal vessel blood oxygen saturation measurements using poly-bead solutions of varying concentrations. Eight healthy, young, non-smoking individuals were enrolled for this study. All subjects underwent digital blood pressure measurements, assessment of non-contact intraocular pressure, pupil dilation and retinal ...

نمودار تعداد نتایج جستجو در هر سال