نتایج جستجو برای: pedicular screw

تعداد نتایج: 16302  

2016
Julia Henschel Sebastian Eberle Peter Augat

BACKGROUND It has been observed clinically that the Z-effect is a potential cause of failure of an intramedullary nail with two cephalic screws. It describes the migration behavior of the cephalic screws in the femoral head. The primary objective was to examine different cephalic screw configurations and test the load distribution between them as a function of their relative placement and their...

2013
Da Liu Yi Zhang Bo Zhang Qing-yun Xie Cai-ru Wang Jin-biao Liu Dong-fa Liao Kai Jiang Wei Lei Xian-ming Pan

BACKGROUND It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. METHODOLOGY/PRINCIPAL F...

Journal: :Technology and health care : official journal of the European Society for Engineering and Medicine 2014
H Goost C Deborre D C Wirtz C Burger A Prescher C Fölsch R Pflugmacher K Kabir

BACKGROUND Pedicle screw pullout due to poor bone quality, mainly caused by osteoporosis, is a common problem in spine surgery. Special implants and techniques, especially PMMA augmentation, were developed to improve the fixation of pedicle screws. PMMA injection into a pilot hole or through a screw involves the same risks as vertebroplasty or kyphoplasty, regardless of the technique used. Espe...

Journal: :the archives of bone and joint surgery 0
mohammad emami department of orthopedic surgery, shahid beheshti uni- versity of medical sciences, tehran, iran. ali reza manafi department of orthopedic surgery, shahid beheshti uni- versity of medical sciences, tehran, iran. behroz hashemi department of orthopedic surgery, shahid beheshti university of medical sciences, tehran, iran. ali nemati department of orthopedic surgery, shahid beheshti uni- versity of medical sciences, tehran, iran. saeed safari department of orthopedic surgery, shahid beheshti uni- versity of medical sciences, tehran, iran.

background: at present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. the aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (dhs) and bipolar hemiarthroplasty in elderly patients with background medical conditions. methods: in this randomi...

Journal: :archives of trauma research 0
sascha rausch trauma department, jena university hospital, jena, germany; trauma department, jena university hospital, jena, germany. tel: +49-36419322889, fax: +49-36419322802 ivan marintschev trauma department, jena university hospital, jena, germany isabel graul trauma department, jena university hospital, jena, germany arne wilharm trauma department, jena university hospital, jena, germany kajetan klos foot and ankle department, catholic medical center, mainz, germany gunther o. hofmann trauma department, jena university hospital, jena, germany; berufsgenossenschaftliche kliniken bergmannstrost halle, halle, germany

conclusions we recommend the additional 2d-fluoroscopic tangential view for detection of screw misplacements caused by overlength, with penetration on the dorsal cortical surface of the distal radius, predominantly observed for the most lateral screw position. the use of intraoperative 3d fluoroscopy did not become accepted in our clinical routine, due to the technical demanding and time consum...

2000
Gordon R. Pennock Patrick J. Meehan

The paper begins with a review of screw algebra including dual numbers, unit line vectors, dual vectors, screws, line coordinates, and screw coordinates and summarizes the essential rules of operation for screw algebra. A significant advantage of the algebra is that geometric, kinematic, and dynamic equations of a rigid body can be expressed in a concise and compact form. Several physical quant...

Journal: :Spine 2000
K Abumi Y Shono M Ito H Taneichi Y Kotani K Kaneda

STUDY DESIGN Retrospective evaluation of complications in 180 consecutive patients with cervical disorders who had been treated by using pedicle screw fixation systems. OBJECTIVES To determine the risks associated with pedicle screw fixation in the cervical spine and to emphasize the importance of preoperative planning and surgical techniques in reducing the risks of this procedure. SUMMARY...

2018
Minfei Qiang Xiaoyang Jia Yanxi Chen Kun Zhang Haobo Li Yuchen Jiang Yijie Zhang

BACKGROUND Screw perforation and varus collapse are common complications of treatment with a PHILOS (proximal humerus internal locking system) plate for proximal humerus fractures, which are associated with improper screw length selection and lack of medial column support. The purposes of this study were: (1) to measure the proper length of periarticular screws of the PHILOS plate in the humera...

2015
Jin-Bum Kim Seung-Won Park Young-Seok Lee Taek-Kyun Nam Yong-Sook Park Young-Baeg Kim

OBJECTIVE To investigate risk factors for S1 screw loosening after lumbosacral fusion, including spinopelvic parameters and paraspinal muscles. METHODS We studied with 156 patients with degenerative lumbar disease who underwent lumbosacral interbody fusion and pedicle screw fixation including the level of L5-S1 between 2005 and 2012. The patients were divided into loosening and non-loosening ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید