Journal: :Physics in medicine and biology 2011
Xinhua Li Da Zhang Bob Liu

The CT scanner-displayed radiation dose information is based on CT dose index (CTDI) over an integration length of 100 mm (CTDI(100)), which is lower than the CTDI over an infinite integration length (CTDI(∞)). In an adult or a pediatric body CT scan, the limiting equilibrium dose can be established near the central scan plane, and CTDI(∞) more closely indicates the accumulated dose than CTDI(1...

2010
Jina Chang Tae‐Suk Suh Dong‐Soo Lee

The deformable lung phantom was developed to account for the patient breathing motion, and to evaluate for a deformable image registration algorithm. The phantom consisted of an acryl cylinder filled with water and a latex balloon located in the inner space of the cylinder. A silicon membrane was attached to the inferior end of the phantom. This silicon membrane was designed to simulate a real ...

Journal: :Physics in medicine and biology 2000
M J Butson R Elferink T Cheung P K Yu M Stokes K Y Quach P Metcalfe

Verification of calculated lung dose in an anthropomorphic phantom is performed using two dosimetry media. Dosimetry is complicated by factors such as variations in density at slice interfaces and appropriate position on CT scanning slice to accommodate these factors. Dose in lung for a 6 MV and 10 MV anterior-posterior field was calculated with a collapsed cone convolution method using an ADAC...

Journal: :Bio-medical materials and engineering 2015
Lung Fa Pan Erdenetsetseg Erdene Chun Chi Chen Lung Kwang Pan

In this study, the phantom imaging quality of 64-slice CT acquisition protocol was quantitatively evaluated using Taguchi. The phantom acrylic line group was designed and assembled with multiple layers of solid water plate in order to imitate the adult abdomen, and scanned with Philips brilliance CT in order to simulate a clinical examination. According to the Taguchi L8(2(7)) orthogonal array,...

Journal: :AJR. American journal of roentgenology 1981
C E Seibert J E Barnes J N Dreisbach W B Swanson R J Heck

Computed tomography (CT) using metrizamide is a valuable tool in the neuroradiologic evaluation of the spinal cord, but CT must be used with care when measuring object size because size may vary with different window center (level) settings. A simple method to determine appropriate window center (level) settings during CT object measurement is described. A polystyrene core with a Teflon outer c...

2012
J. Wünscher Hannes Kenngott Martin Wagner Felix Nickel Beat P. Müller-Stich

Das HELIOS Phantom (Heidelberg Laparoscopic Intervention and Operation Simulator) stellt ein menschennahes Phantom mit einem Torso aus Kunststoff und Organen aus Silikon auf der Basis einer Computertomographie eines Patienten dar. Das Phantom dient als Evaluationsplattform für sämtliche Belange in der computerund roboterassistierten Chirurgie, des Weiteren ist es als Trainingsphantom für die la...

Journal: :Medical physics 2009
N Mail D J Moseley J H Siewerdsen D A Jaffray

The large variation of x-ray fluence at the detector in cone-beam CT (CBCT) poses a significant challenge to detectors' limited dynamic range, resulting in the loss of skinline as well as reduction of CT number accuracy, contrast-to-noise ratio, and image uniformity. The authors investigate the performance of a bowtie filter implemented in a system for image-guided radiation therapy (Elekta onc...

Journal: :Physical review 2023

This highly original paper relates the $e\phantom{\rule{0}{0ex}}x\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}c\phantom{\rule{0}{0ex}}t$ $r\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}n\phantom{\rule{0}{0ex}}o\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}m\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}l\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}z\phantom{\rule{0}{0ex}}a\phantom{\rule{0...

2016
Youcef El-Mohri Larry E Antonuk Richard B Choroszucha Yi Wang Qihua Zhao

Beams-eye-view imaging applications such as real-time soft-tissue motion estimation are hindered by the inherently low image contrast of electronic portal imaging devices (EPID) currently available for clinical use. We introduce and characterize a novel EPID design that provides substantially increased detective quantum efficiency (DQE), contrast-to-noise ratio (CNR) and sensitivity without deg...

Journal: :Journal of Applied Clinical Medical Physics 2019