نتایج جستجو برای: proximal humerus fracture sequelae
تعداد نتایج: 175099 فیلتر نتایج به سال:
This study evaluated forearm compartment pressures in 29 children with supracondylar humerus fractures. Pressures were measured before and after reduction in the dorsal, superficial volar, and deep volar compartments at the proximal 1/6th and proximal 1/3rd forearm. Pressures in the deep volar compartment were significantly elevated compared with pressures in other compartments. There were also...
Proximal humeral epiphyseal plate fracture in a collegiate track and field decathlete: a case study.
OBJECTIVE To present the case of an 18-year-old collegiate decathlete with a Salter-Harris type I epiphyseal plate fracture of the proximal humerus. BACKGROUND A collegiate decathlete was playing flag football and fell on an outstretched arm. He was taken to the emergency room and diagnosed with a type I epiphyseal plate fracture. DIFFERENTIAL DIAGNOSIS AC sprain, dislocation or subluxation...
We retrospectively studied 14 patients with proximal and diaphyseal tumours and disappearing bone (Gorham's) disease of the humerus treated with wide resection and reconstruction using an allograft-resurfacing composite (ARC). There were ten women and four men, with a mean age of 35 years (8 to 69). At a mean follow-up of 25 months (10 to 89), two patients had a fracture of the allograft. In on...
BACKGROUND Proximal humerus fractures can be treated surgically (eg: pinning, plate and screws) or conservatively by wearing a splint or a cast. Following both of these approaches, rehabilitation has proven effective to prevent functional limitations and to re-establish normal shoulder function. However, access to these rehabilitation services and compliance tends to be limited in elderly patie...
PURPOSE. To compare the efficacy of locking plate fixation with and without inferomedial screws in maintaining the reduction of a proximal humeral fracture. METHODS. 22 synthetic humerus models were used. A standardised 3-part proximal humeral fracture with a 4-mm wedge segment was created and fixed with a locking plate and screws with (n=11) and without (n=11) inferomedial screws. The intrafra...
Osteoarticular amyloidosis can be one of the musculoskeletal system manifestations related to dialysis. We share our experience in dealing with a case of disseminated haemodialysis-associated amyloidosis in a 74-year-old end-stage renal failure patient. This patient suffered from a serious complication, namely an unprovoked pathological fracture at the basal neck region of the right femur. Poly...
The four-part fracture complex described by Neer is a rare but severely disabling injury to the proximal humerus [18]. It is an injury which, while historically rare, has become increasingly more common as the population ages and remains physiologically active. This injury is specifically disabling when it involves the dominant arm. The severity of this injury is due to the associated vascular ...
Primary hemiarthroplasty of the shoulder is an accepted procedure to treat complex proximal humeral fractures. The goal of this study was to assess the functional outcome in patients treated with hemiarthroplasty using a custom offset shoulder prosthesis, either for an acute four-part fracture of the proximal humerus or following failed primary treatment of a complex humeral fracture. Thirty se...
AIM To investigate non-ossifying fibromas (NOFs) common fibrous bone lesions in children that occur in bones of the lower extremities. METHODS We analyzed 44 cases of NOF including 47 lesions, which were referred with a working diagnosis of neoplastic lesions. Lesions were located in the upper extremities (1 proximal humerus, 1 distal radius) and the lower extremities (25 distal femurs, 12 pr...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید