نتایج جستجو برای: ultrasound power

تعداد نتایج: 592500  

Journal: :Circulation 2009
Stéphane Cook Elena Ladich Gaku Nakazawa Parham Eshtehardi Michel Neidhart Rolf Vogel Mario Togni Peter Wenaweser Michael Billinger Christian Seiler Steffen Gay Bernhard Meier Werner J Pichler Peter Jüni Renu Virmani Stephan Windecker

BACKGROUND Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. ...

Journal: :Applied sciences 2022

The main purpose of this study was to select the appropriate ultrasound parameters that support freezing process Bo Chinh ginseng. This involves placing ginseng in an open-air environment and ensuring transducer does not come into contact with material. research results show power, irradiation temperature intermittency ratio all affect time, nucleation temperature, color microstructure material...

Journal: :Collegium antropologicum 2011
Antonio Petosić Bojan Ivancević Dragoljub Svilar Tihomir Stimac Josip Paladino Darko Oresković Ivana Jurjević Marijan Klarica

Measurement of the acoustic power in high-energy ultrasonic devices is complex due to occurrence of the strong cavitation in front of the sonotrode tip. In our research we used three methods for characterization of our new ultrasonic probe for neuroendoscopic procedures. The first method is based on the electromechanical characterization of the device measuring the displacement of the sonotrode...

2015
Zahra Izadifar George Belev Paul Babyn Dean Chapman

BACKGROUND The observation of ultrasound generated cavitation bubbles deep in tissue is very difficult. The development of an imaging method capable of investigating cavitation bubbles in tissue would improve the efficiency and application of ultrasound in the clinic. Among the previous imaging modalities capable of detecting cavitation bubbles in vivo, the acoustic detection technique has the ...

2015
Da Eun Lee So Yun Park Sa Ra Lee Kyungah Jeong Hye Won Chung

OBJECTIVES To determine the diagnostic performance of transrectal ultrasound in virgin patients with polycystic ovary syndrome (PCOS) by receiver operating characteristic (ROC) curve analysis, compared with conventional transvaginal ultrasound assessment. METHODS Ultrasound examinations were performed in 963 Korean women, with transvaginal transducers in 677 women and transrectal transducers ...

2001
Takayuki IWAMOTO Taro MAEDA Hiroyuki SHINODA

We studied on the feasibility of focused ultrasound for tactile feeling display. Our experiments showed that focused ultrasound at 1 MHz and 5 MHz effected our somatic sensation both by its radiation pressure and by direct stimulation to the nerve structures. The radiation pressure force generated by our apparatus was 0.23 gf/cm per 1-watt power consumption and evoked tactile feeling stably, wh...

2013
Lisa Newcombe Jim Woodburn Duncan Porter Sarah Saunders David McCarey Monica Gupta Debbie Turner

Methods Patients with early RA were assessed prospectively for 12 months using high-resolution B-mode and Power Doppler (PD) ultrasound. A cumulative ultrasound score was derived to measure change in the presence of joint effusions, synovitis, erosions, PD, and tenosynovitis between baseline and 12 months. Change in scores was calculated alongside change in global disease (DAS28), disability (H...

2013
Yufeng Zhou

Ultrasound is a popular imaging modality for its safety and low cost. Its role in the diagnosis of breast cancer is discussed, and its performance is then compared those of mammography (gold standard) and MRI. Besides conventional B-mode and color or power Doppler ultrasound images, latest development of acoustic radiation force impulse (ARFI) and supersonic shear imaging and their application ...

Journal: :Surgical neurology 2006
Ola M Rygh Toril A Nagelhus Hernes Frank Lindseth Tormod Selbekk Tomm Brostrup Müller Geirmund Unsgaard

BACKGROUND Avoiding damage to blood vessels is often the concern of the neurosurgeon during tumor surgery. Using angiographic image data in neuronavigation may be useful in cases where vascular anatomy is of special interest. Since 2003, we have routinely used 3D ultrasound angiography in tumor surgery, and between January 2003 and May 2005, 62 patients with different tumors have been operated ...

This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...