نتایج جستجو برای: velocity cross plot
تعداد نتایج: 653337 فیلتر نتایج به سال:
PREVIOUS papers1 in this series have dealt with (a) the evaluation of radial wavefunctions, phase shifts, reduced phases, and differential elastic cross sections for scattering by a L-J (12, 6) potential; (b) the resulting velocity dependence of the differential and total scattering cross sections, with attention given to the Jeffreys-Born OB) approximation for the higher-order phases; (c) the ...
7 We apply two different algorithms to measure surface-wave phase velocity, as a function of 8 frequency, from seismic ambient noise recorded at pairs of stations from a large European 9 network. The two methods are based on consistent theoretical formulations, but differ in the 10 implementation: one method involves the time-domain cross-correlation of signal recorded 11 at different stations;...
7 We apply two different algorithms to measure surface-wave phase velocity, as a function of 8 frequency, from seismic ambient noise recorded at pairs of stations from a large European 9 network. The two methods are based on consistent theoretical formulations, but differ in the 10 implementation: one method involves the time-domain cross-correlation of signal recorded 11 at different stations;...
PURPOSE To provide transcranial color-coded duplex flow-velocity data for the basal cerebral arteries in patients with unilateral flow-restrictive extracranial carotid artery disease, and to compare these data with the flow velocities obtained in healthy control subjects. METHODS Transcranial color-coded duplex sonography was performed in 78 patients with different patterns of cross flow thro...
• A submitted manuscript is the author's version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website. • The final author version ...
The coronary Doppler catheter has been used primarily in the measurement of coronary vasodilator reserve, most often as the ratio of peak to resting velocity in response to an intracoronary dose of papaverine. We have developed a new method based on the continuity equation using a Doppler catheter for the assessment of stenosis severity in the coronary circulation by means of quantitative veloc...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید