نتایج جستجو برای: wall shear stress

تعداد نتایج: 647164  

Journal: :مهندسی سازه 0
محمدعلی لطف اللهی یقین

the combination of flexural frame and shear wall is one of the suitable systems to apply in reinforced concrete buildings. the deflections of flexural frame become limited due to the high stiffness of wall and the interaction of these systems. tall buildings even higher than fifty stories can be designed by using frame- wall systems. with respect to special behavior of flexural frame or shear w...

2012
B K Thakkar

Design of shear walls is a complex procedure, especially if the cross section of the shear wall is not regular in shape. Shear walls are usually treated like cantilevers fixed at the foundation level. Normally, lift wells are designed as shear walls. The design of shear walls takes horizontal forces into account by shear and bending. Design for shear in the walls can be managed by computing the...

Journal: :Medical engineering & physics 2016
Sophia Sakellariou Wenguang Li Manosh C Paul Giles Roditi

Iodinated contrast media (CM) are the most commonly used injectables in radiology today. A range of different media are commercially available, combining various physical and chemical characteristics (ionic state, osmolality, viscosity) and thus exhibiting distinct in vivo behaviour and safety profiles. In this paper, numerical simulations of blood flow with contrast media were conducted to inv...

Journal: :Microcirculation 2002
Michael L Smith McRae J Smith Michael B Lawrence Klaus Ley

OBJECTIVE To determine whether selectin-mediated leukocyte-rolling velocity in inflamed venules in vivo is determined by wall shear rate (WSR) or by wall shear stress (WSS). METHODS WSS was manipulated independently of WSR by altering the viscosity of blood plasma in mice with an isovolemic exchange of blood for low- or high-viscosity dextran solutions. Rolling of neutrophils or beads coated ...

2009
S. Sillanpää M. Heinonen

In a dynamic weighing gas mass flow measurement, the gas mass flow rate is continuously determined by weighing a gas mass loss from a gas cylinder as a function of time. In this measurement method, the temperature difference between the wall of the gas cylinder and ambient air cannot be avoided. Due to natural convection flow, a shear stress appears on the wall of the cylinder. Because of the d...

Journal: :American journal of physiology. Heart and circulatory physiology 2008
Ufuk Olgac Vartan Kurtcuoglu Dimos Poulikakos

The work herein represents a novel approach for the modeling of low-density lipoprotein (LDL) transport from the artery lumen into the arterial wall, taking into account the effects of local wall shear stress (WSS) on the endothelial cell layer and its pathways of volume and solute flux. We have simulated LDL transport in an axisymmetric representation of a stenosed coronary artery, where the e...

2015
Claudio Carallo Maria Serena De Franceschi Cesare Tripolino Claudio Iovane Serena Catalano Amerigo Giudice Antonio Crispino Michele Figliuzzi Concetta Irace Leonzio Fortunato Agostino Gnasso Suzanne Buhrow.

Periodontal disease is associated with endothelial dysfunction of the brachial artery and hemodynamic alterations of the common carotid artery. Periodontal therapy improves endothelial function. It is not known if it is able also to improve the hemodynamics of the carotid artery. The aim of the current study was to evaluate the efficacy of 2 different periodontal treatments on carotid hemodynam...

2006
J. P. Monty M. S. Chong I. Marusic

A lightweight, high frequency response, floating element sensor was used to measure wall shear stress fluctuations in an atmospheric surface layer. The sensor uses a laser position measurement system to track the motion of the floating element. The measurements were taken as part of an internationally coordinated experimental program designed to make extensive spatial and temporal measurements ...

2015
Nosheen Zareen Khan Abdul Majeed Siddiqui Muhammad Afzal Rana

Abstract---The steady flow of a second order fluid through constricted tube with slip velocity at wall is modeled and analyzed theoretically. The governing equations are simplified by implying no slip in radial direction. Based on Karman Pohlhausen procedure polynomial solution for axial velocity profile is presented. Expressions for pressure gradient, shear stress, separation and reattachment ...

Journal: :Bio-medical materials and engineering 2014
Natalia Veshkina Ireneusz Zbicinski Ludomir Stefańczyk

In this study, a fluid-structure interaction analysis based on the application of patient-specific mechanical parameters of the aneurismal walls was carried out to predict the rupture side during an abdominal aortic aneurysm (AAA). Realistic geometry of the aneurysm was reconstructed from CT data acquired from the patient, and patient-specific flow conditions were applied as boundary conditions...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید