BACKGROUND Electrocardiographic gated 13N-ammonia positron emission tomography (PET) enables simultaneous assessment of myocardial blood flow and left ventricular (LV) function. The aim of this study was to assess the accuracy of gated 13N-ammonia PET for evaluating global and regional LV function in patients with coronary artery disease (CAD) in comparison with conventional left ventriculograp...
Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided in...
Cardiac PET imaging using 13N-ammonia and 18FDG was performed on 17 normal volunteers in the glucose-loaded and fasted states. PET images (glucose-loaded and fasted) were subjected to qualitative visual analysis using the descriptors: image quality, FDG blood-pool activity, ammonia lung field activity, and clinical interpretability. Glucose-loaded studies had better image quality, diminished FD...
PURPOSE The aim of the study was to evaluate the efficacy of 13N-ammonia and 18F-fluorodeoxyglucose (18F-FDG) PET performed on the same day in the detection of advanced prostate cancer (PC) and its metastases. PATIENTS AND METHODS Twenty-six patients with high-risk PC [Gleason score 8-10 or prostate-specific antigen (PSA)> 20 ng/ml or clinical tumor extension ≥ T2c] were recruited into the st...
ABSTACT OBJECTIVES: Myocardial blood flow (MBF) imaging is used in patients with suspected cardiac sarcoidosis, and also in stress/rest studies. The accuracy of MBF is dependent on imaging parameters such as new reconstruction methodologies. In this work, we aim to assess the impact of a novel PET reconstruction algorithm (Bayesian-penalized likelihood-BPL) on the values determined from the cal...
در این مقاله به بررسی شرایط بهینه برای تولید رادیوایزوتوپ 13N توسط واکنش 12C(d,n)13N در دستگاه پلاسمای کانونی با نرخ تکرار پرداخته شده است. با محاسبهی اکتیویتهی طیفهای تجربی دوترون و بررسی تأثیر نرخ تکرار بر روی اکتیویته نشان دادهایم که اکتیویته و نرخ تکرار با همدیگر رابطهای خطی دارند. محاسبات نشان میدهند که با افزایش نرخ تکرار، امکان افزایش اکتیویتهی تولیدی در یک دستگاه پلاسمای کانونی ن...
A simple double liquid chamber target was developed to provide the option for simultaneous production of [15O]H2O and either 13N or 18F using a single proton beam. Irradiation of natural water in a thin aluminium front chamber produced [15O]H2O by the 16O(p, pn)15O reaction directly. Large (0.5-1.0 Ci) doses of sterile [15O]H2O (greater than 99.95% radionuclide purity) were routinely prepared i...
Ammonia and 6-glutamine, labeled with N-13, were tested as imaging agents for a variety of spontaneous canine tumors. The imaging capabilities of these compounds were compared with each other, with other scanning agents, and with radiologic and pathologic procedures. Good agreement between positive gamma images and postmortem findings occurred in 11 of 15 cases with [13N] ammonia as the localiz...
In vivo studies with L-[13N]glutamate in the Walker 256 carcinosarcoma implanted under the renal capsule of female Sprague-Dawley rats demonstrate that uptake of glutamate and the rate of incorporation of the nitrogen label from this amino acid into metabolites is slower in the tumor than in nontumorous kidney tissue. Glutamate dehydrogenase, glutaminase, and alanine aminotransferase activities...