نتایج جستجو برای: 39 dosimeter
تعداد نتایج: 99212 فیلتر نتایج به سال:
The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filte...
OBJECTIVES/HYPOTHESIS Voice rest is frequently recommended following surgical disruption of vocal fold epithelium, but patients report variable adherence to voice rest recommendations. The objective of this study was to assess the clinical utility of an ambulatory vocal dosimeter for measuring adherence to voice rest recommendations. STUDY DESIGN Outcomes research. METHODS Part 1: To determ...
CR-39 plastic detectors were used for fast neutron dose mapping in the radiotherapy facility at King AbdulAziz University Hospital (KAUH). Detectors were calibrated using a Cf neutron source and a neutron dosimeter. After exposure chemical etching was performed using 6N NaOH solution at 70 C. Tracks were counted using an optical microscope and the number of tracks/cm was converted to a neutron ...
A new inhalation synchronised dosimeter triggered by low inspiratory flow rates has been assessed. The methacholine challenge test using dosimeter nebulisation with controlled tidal breathing was compared with continuous nebulisation using De Vilbiss No 40 nebulisers with deep inhalations in 11 asthmatic subjects. Within subject PD20 FEV1 values were lower with the dosimeter method than with th...
PURPOSE To evaluate the suitability of the GD-301 glass dosimeter for use in in vivo dose verification in proton therapy. METHODS The glass dosimeter was analyzed for its dosimetric characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stair-like holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurement...
Radiation processing in many areas, particularly in radiation sterilization, demands control of the absorbed dose. Many dosimeters have been proposed for the high-level dose range (region of 10 to 50 kGy). However, in addition to the required reproducibility, reliability or uncertainty (< 5%), it is desirable for radiation processing that the selected dosimetric system is easy to operate. One o...
PURPOSE In optical-CT, the use of a refractively matched polyurethane solid-tank in place of a fluid bath has the potential to greatly increase practical convenience, reduce cost, and possibly improve the efficacy of flood corrections. This work investigates the feasibility of solid-tank optical-CT imaging for 3D dosimetry through computer simulation. METHODS A matlab ray-tracing simulation p...
BACKGROUND Guidelines for the 2-min tidal-breathing and the five-breath dosimeter methods for methacholine challenge have recently been published by the American Thoracic Society (ATS). Although subjects are exposed to twice as much aerosol at any given concentration during the tidal-breathing method compared to the dosimeter method, they were thought to give equivalent results. OBJECTIVE To ...
Bronchial reactivity is being measured with increasing frequency in epidemiological studies, but there debate continues about the relative merits of the different methods used to measure reactivity, particularly for subjects with no previous experience of reactivity testing as is the case in epidemiological studies. Repeatability is likely to improve with practice, and laboratory based studies ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید