نتایج جستجو برای: 3d dosimetry

تعداد نتایج: 196009  

Journal: :Journal of physics. Conference series 2006
Mark Oldham

The need for an accurate, practical, low-cost 3D dosimetry system is becoming ever more critical as modern dose delivery techniques increase in complexity and sophistication. A recent report from the Radiological Physics Center (RPC) (1), revealed that 38% of institutions failed the head-and-neck IMRT phantom credentialing test at the first attempt. This was despite generous passing criteria (w...

2017
Kalin I Penev Meng Wang Kibret Mequanint

Tetrazolium salts (TS) have been previously used for radiochromic dosimetry in solutions, films and three dimensional (3D) gelatine-based gels. However, widespread application for 3D dosimetry has not been achieved due to the required high concentrations and associated high costs of the TS dimer used in prior research. Through careful selection of TS monomer, sensitivity-enhancing additives and...

2013
F Nordström

In this study, a 4D dosimetry concept was developed. This concept included a method for calculation of 3D reference absorbed dose matrices at every control point of the delivery using a clinical treatment planning system (TPS). Further, the gamma evaluation method was extended to incorporate the 4 dimension of the TPS calculated dose distributions. The applications of the 4D dosimetry concept o...

2014
Mauro Valente José Vedelago

Fricke gel dosimetry is a valuable method for in-phantom dose measurements in complex irradiation modalities like IMRT and BNCT. Implementation of this dosimetry technique requires dedicated instruments capable of measuring and further analysis immediately in situ at the radiation facility. This work presents a novel and integral dosimetry system aimed to attain portability requirements. The me...

2013
M Oldham J Newton L Rankine J Adamovics D Kirsch S Das

There is significant interest in delivering precisely targeted small-volume radiation treatments, in the pre-clinical setting, to study dose-volume relationships with tumor control and normal tissue damage. In this work we investigate the IGRT targeting accuracy of the XRad225Cx system from Precision x-Ray using high resolution 3D dosimetry techniques. Initial results revealed a significant tar...

2015
Wietske Woliner-van der Weg Rafke Schoffelen Robert F Hobbs Martin Gotthardt David M Goldenberg Robert M Sharkey Cornelis H Slump Winette TA van der Graaf Wim JG Oyen Otto C Boerman George Sgouros Eric P Visser

BACKGROUND Red bone marrow (RBM) toxicity is dose-limiting in (pretargeted) radioimmunotherapy (RIT). Previous blood-based and two-dimensional (2D) image-based methods have failed to show a clear dose-response relationship. We developed a three-dimensional (3D) image-based RBM dosimetry approach using the Monte Carlo-based 3D radiobiological dosimetry (3D-RD) software and determined its additio...

Journal: :Medical physics 2009
Harshad Sakhalkar David Sterling John Adamovics Geoffrey Ibbott Mark Oldham

This study presents the application of the Presage/optical-CT 3D dosimetry system for relative dosimetry in the Radiologic Physics Center (RPC) Head and Neck (H&N) IMRT phantom. Performance of the system was evaluated by comparison with the "gold-standard" RPC credentialing test. A modified Presage cylindrical insert was created that extended the capability of the RPC H&N phantom to 3D dosimetr...

Journal: :Journal of Physics: Conference Series 2015

2010
M. Lawrence T. Cullip L. Potter S. Wang Z. Xu K. Burkhardt S. Chang

Intensity-modulated radiation therapy (IMRT) quality assurance (QA) is often performed using a 2D device and compares measured and computed fluence maps to determine if a field passes or fails certain dose and position criteria. The effects of a measured deviation to the 3D patient spatial dosimetry and dose volume histogram (DVH) are largely unknown because they cannot be analyzed using commer...

Journal: :Physics in medicine and biology 2013
Jan Vandecasteele Yves De Deene

A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed to a 6 MV photon beam and the depth dose was compared against a diamond detecto...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید