نتایج جستجو برای: amplatzer

تعداد نتایج: 1200  

Journal: :Cardiology journal 2017
Caroline Kleinecke Jai-Wun Park Martin Gödde Konstantin Zintl Steffen Schnupp Johannes Brachmann

BACKGROUND The Amplatzer Amulet (St. Jude Medical, Minneapolis, MN, USA) is a second gen-eration Amplatzer device for left atrial appendage (LAA) occlusion (LAAO) for stroke prophylaxis in patients with atrial fibrillation. This research sought to assess the clinical performance of the Amplatzer Amulet device and in follow up for 12 months. METHODS In this single-center registry patients with...

Journal: : 2023

Introduction: Diagnosis and treatment of ventricular septal defect (VSD) during infancy is great importance in improving the infant’s health. Patent ductus arteriosus (PDA) coarctation aorta are most common disorders associated with VSD. needs to be closed using surgical or non-surgical procedures. This article aims present a case repairing by stenting an infant VSD due placement large Amplatze...

Journal: :Journal of the Formosan Medical Association = Taiwan yi zhi 2007
Shan-Miao Lin Haw-Kwei Hwang Ming-Ren Chen

Percutaneous transcatheter atrial septal defect (ASD) closure is a widely used technique that has replaced open-heart surgical closure in many centers. The most common implant is the Amplatzer septal occluder which seems to be a highly effective and safe device. However, there are reports of complications associated with its implantation. We report a 9-year-old boy who presented with complete a...

2013
Alpay Çeliker Fatih Atik

Ventriküler septal defektler transkateter tedavide kapatılması gereken bir defekt olarak görülmektedir. Son yıllarda yeni cihazların bulunması ile birçok merkezde ventriküler septal defektlerin perkütan kapatılması cesaretlendiren sonuçlarla uygulanmaktadır. Amplatzer oklüder sistemlerin son yıllarda kullanılmaya başlaması ile birlikte implantasyon sayılarında artma olmuştur. Bunun yanısıra, mü...

2015
Yi-Sik Kim Sang-Rok Lee

Transcatheter closure of patent ductus arteriosus with the Amplatzer duct occluder shows excellent results. However, there is a risk of device embolization after deployment. We report the case of a 33-year-old man in whom an embolized Amplatzer device was retrieved from the right pulmonary artery by a percutaneous method. We also review this uncommon severe complication and offer technical tips...

Journal: :Texas Heart Institute journal 2012
Pravin K Goel Aditya Kapoor Aditya Batra Roopali Khanna

In selected patients, transcatheter closure of atrial septal defects with the AMPLATZER Septal Occluder has yielded excellent results. However, there is a slight risk of device embolization after deployment. We report the case of a 26-year-old woman in whom an embolized AMPLATZER device was retrieved percutaneously from the right pulmonary artery. We also discuss important technical principles ...

Journal: :Revista espanola de cardiologia 2007
Justo Santiago Manuel Acuña Elizabeth Arispe Ronaldo Camargo Juliana Neves Daniel Arnoni Valmir F Fontes Carlos A Pedra

The association of a right aortic arch with an ipsilateral patent ductus arteriosus is rare, especially when there are no other intracardiac anomalies. We report three female patients aged 26, 35 and 9 years with this combination in whom previous attempts at surgical closure by thoracotomy and sternotomy were unsuccessful and who subsequently underwent successful percutaneous closure of the def...

Journal: :Cardiology in the young 2013
Yifei Li Kaiyu Zhou Yimin Hua Chuan Wang Liang Xie Jie Fang Xin Rong Jiantong Shen

OBJECTIVE Percutaneous transcatheter occlusion has benefited thousands of patients suffering from patent foramen ovale and atrial septal defect. However, no general agreement has been reached on the superiority among occluders. Thus, a meta-analysis between the two most commonly adopted types of occluders was conducted. METHODS The literature review has identified relevant studies up to May, ...

Journal: :Archives of cardiovascular diseases 2009
Sylvia Abadir Younes Boudjemline Christian Rey Jérome Petit François Sassolas Philippe Acar Alain Fraisse Claire Dauphin Jean-François Piechaud Alain Chantepie Jean-René Lusson

BACKGROUND Percutaneous closure of large persistent ductus arteriosus using the Amplatzer duct occluder is an alternative to surgery. However, this device is not recommended in infants weighing less than 6 kg. AIM To evaluate the safety and effectiveness of this procedure in low-body-weight infants. METHODS We reviewed retrospectively data for infants weighing less or equal to 6 kg who unde...

2017
Enfa Zhao Wenjuan Liu Yushun Zhang Gesheng Cheng Yajuan Du Lu He Xingye Wang Xumei He

BACKGROUND Amplatzer occluder and Cardio-O-fix occluder are currently used in percutaneous closure of patent foramen ovale. However, there is still a lack of relevant reports comparison the differences between them. The aim of this study was to evaluate the short-term and mid-term safety and efficacy of the Cardi-O-fix occluder in preventing recurrent cerebrovascular events in patients with a p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید