نتایج جستجو برای: aseptic glenoid loosening

تعداد نتایج: 9837  

Journal: :The Journal of bone and joint surgery. British volume 2004
F Sirveaux L Favard D Oudet D Huquet G Walch D Molé

We reviewed 80 shoulders (77 patients) at a mean follow-up of 44 months after insertion of a Grammont inverted shoulder prosthesis. Three implants had failed and had been revised. The mean Constant score had increased from 22.6 points pre-operatively to 65.6 points at review. In 96% of these shoulders there was no or only minimal pain. The mean active forward elevation increased from 73 degrees...

Journal: :Journal of shoulder and elbow surgery 2009
Eric J Strauss Chris Roche Pierre-Henri Flurin Thomas Wright Joseph D Zuckerman

Total shoulder arthroplasty is a common treatment for glenohumeral arthritis. One of the most common failure modes of total shoulder arthroplasty is glenoid loosening, causing postoperative pain, limitation of function, and potentially, the need for revision surgery. The literature has devoted considerable attention to the design of the glenoid component; efforts to better understand the biomec...

Journal: :PloS one 2016
Patrick Stelmach Christian Wedemeyer Lena Fuest Gina Kurscheid Thorsten Gehrke Stefanie Klenke Marcus Jäger Max D Kauther Hagen S Bachmann

Aseptic loosening is a major cause of revision surgery of total hip arthroplasty (THA). Only few host factors affecting aseptic loosening have been identified until now, although they are urgently needed to identify and possibly treat those patients at higher risk for aseptic loosening. To determine whether the functional single nucleotide polymorphism (SNP) c.-938C>A (rs2279115), located in th...

Journal: :The Journal of bone and joint surgery. British volume 2009
A Cil C J H Veillette J Sanchez-Sotelo J W Sperling C Schleck R H Cofield

Between 1976 and 2004, 38 revision arthroplasties (35 patients) were performed for aseptic loosening of the humeral component. The mean interval from primary arthroplasty to revision was 7.1 years (0.4 to 16.6). A total of 35 shoulders (32 patients) were available for review at a mean follow-up of seven years (2 to 19.3). Pre-operatively, 34 patients (97%) had moderate or severe pain; at final ...

Journal: :The Journal of bone and joint surgery. British volume 2010
J F Cazeneuve D-J Cristofari

We have previously described the short-term outcome of the use of reverse shoulder arthroplasty in the treatment of acute complex proximal humeral fractures in the elderly. We now report the clinical and radiological outcome of 36 fractures at a mean of 6.6 years (1 to 16). Previously, at a mean follow-up of 6 years (1 to 12) the mean Constant score was 58.5; this was reduced to 53 points with ...

Journal: :Journal of shoulder and elbow surgery 2009
Shane J Nho Denis Nam Owen L Ala Edward V Craig Russell F Warren Timothy M Wright

HYPOTHESIS Polyethylene components retrieved at revision of total knee and hip replacements have been analyzed to study the effect of design, patient, and surgical factors on initial implant performance, but few studies have reported similar types of findings in retrieved glenoids. MATERIALS AND METHODS From 1979 to 2006, 78 glenoid components were retrieved from revision surgery in 73 patien...

2010
Jiri Gallo Vitezslav Havranek Jana Zapletalova Jiri Lostak

BACKGROUND We studied which factor could predict aseptic loosening in ABG I hip prosthesis with hydroxyapatite coating. Aseptic loosening and periprosthetic osteolysis are believed to be caused, at least in part, by increased polyethylene (PE) wear rate via particle disease. Based on it, increased PE wear rate should be associated with aseptic loosening regardless of the type of implant. METH...

2009

INTRODUCTION: Polyethylene wear is a recurrent problem in joint arthroplasty. In addition to permanent deformation or complete destruction of the component, small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. In anatomic total shoulder arthroplast...

Journal: :The Journal of bone and joint surgery. British volume 2011
A Young G Walch P Boileau L Favard F Gohlke M Loew D Molé

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome ...

2017
Oystein Gothesen Stein Hakon L Lygre Michelle Lorimer Stephen Graves Ove Furnes

Background and purpose - Given similar functional outcomes with mobile and fixed bearings, a difference in survivorship may favor either. This study investigated the risk of aseptic loosening for the most used subtypes of mobile-bearing rotating-platform knees, in Norway and Australia. Patients and methods - Primary TKRs reported to the Norwegian and Australian joint registries, between 2003 an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید