نتایج جستجو برای: atrial septal occluder device surgical procedures
تعداد نتایج: 1232896 فیلتر نتایج به سال:
We carried out transcatheter procedures to close postinfarction ventricular septal defects (PIVSDs) in 19 patients: two had recanalization after surgical closure, and 17 had a primary PIVSD. In three of the latter patients, who had acute PIVSDs, the procedure was carried out in the first 3 weeks after infarction; in the 13 patients with subacute PIVSD, it was carried out 3.5-12 weeks after infa...
OBJECTIVES The aim of this study is to evaluate our clinical experience using an Amplatzer septal occluder for catheter closure of a secundum atrial septal defect under transthoracic echocardiography guidance without general anaesthesia. METHODS Patients eligible for transcatheter atrial septal defect closure were selected using transthoracic echocardiography. The largest defect diameter meas...
OBJECTIVES This study sought to compare the safety and efficacy of the HELEX septal occluder (HSO) with surgical repair of atrial septal defect (ASD). BACKGROUND The HSO is a low-profile, double-disk occluder device for percutaneous closure of secundum ASD. METHODS Patients were enrolled (HSO arm prospectively, surgery arm prospectively/retrospectively) from 14 U.S. sites and followed up fo...
Percutaneous closure of atrial septal defect (ASD) has become an increasingly common procedure. Serious complications of the procedure, such as cardiac migration, are rare, and usually occur <72 hours after device placement. In this report, we present the case of a patient who underwent successful surgical treatment for the migration of an ASD occluder device to the thoracic aorta 12 months aft...
this is a case presentation of a 26-year-old woman with a moderate-sized atrial septal secundum defect (17mm) who underwent catheterism, during which an amplatzer septal occluder number 26 was inserted successfully. on the second postoperative day, she deteriorated and a clinical examination showed a typical tamponade. after a percutaneous aspiration of the pericardial cavity and transient impr...
Percutaneous transcatheter atrial septal defect (ASD) closure is a widely used technique that has replaced open-heart surgical closure in many centers. The most common implant is the Amplatzer septal occluder which seems to be a highly effective and safe device. However, there are reports of complications associated with its implantation. We report a 9-year-old boy who presented with complete a...
We describe a 17-year-old patient with an atrial septal defect who underwent device closure with a second generation Sideris buttoned device at 4 years of age. She presented 13 years after the procedure with the acute onset of chest discomfort, at which time a chest radiograph showed migration of the wire of the right atrial counter-occluder to the lateral aspect of the right atrial wall, with ...
PURPOSE For the successful completion of transcatheter closure of atrial septal defects with the Amplatzer septal occluder, shape of the defects should be considered prior to selecting the device. The purpose of this study is to evaluate the results of a transcatheter closure of oval shaped atrial septal defect. MATERIALS AND METHODS From November 2009 until November 2011, cardiac computed to...
Atrial septal defect (ASD) is a congenital heart defect that is being increasingly treated using percutaneous interventions. However, these techniques are not devoid of complications. One such complication is device embolization. Removal of such closure device poses tremendous risk and consequent complications both by percutaneous retrieval and surgical removal. Herein, we present two cases of ...
OBJECTIVE The objective of this study was to assess predictors of residual shunts after percutaneous patent foramen ovale (PFO) closure with Amplatzer PFO occluder (AGA Medical Corporation, Golden Valley, MN, USA). METHODS All percutaneous PFO closures, using Amplatzer PFO occluder performed at a tertiary center between May 2002 and August 2006, were reviewed. Follow-up, including saline cont...
نمودار تعداد نتایج جستجو در هر سال