Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...

Abbas Takavar Davood Beiki, Mehdi Sohrabi Mohammad Eftekhari, Mohsen Saghari N Mostaghim

SPECT detects γ-rays from administered radiopharmaceutical within the patient body. γ-rays pass through different tissues before reaching detectors and are attenuated. Attenuation can cause artifacts; therefore different methods are used to minimize attenuation effects. In our study efficacy of Chang method was evaluated for attenuation purpose, using a custom made heart phantom. Due to d...

Journal: :iranian journal of nuclear medicine 2006
mohsen bakhshandeh hossein rajabi masoud vafamanesh ali akbar sharafi shahram seifollahi

introduction: nowadays, imaging of the myocardial perfusion (mpi) using the single photon emission tomography (spet) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. in contrast to the coronary artery angiography, mpi is non-invasive, less expensive and more physiological. unfortunately, this image is affected by the some artifacts. these arti...

Alireza Kamali asl Faezeh Vedaei Faraz Kalantari, Mohammad Reza Ay Mojtaba Ansari

Introduction: Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Single Photon Emission Computed Tomography (SPECT) images. The aim of present study was to investigate the effect of attenuation correction on the detection of activation foci following statistical analysis w...

M. Amoui, M. Hosntalab, M.R. Teimoori Sichani, Sh. Akhlaghpoor,

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

Journal: :iranian journal of radiation research 0
a. vahidian kamyad department of mathematic, ferdowsi university, mashad, iran m.h. noori eskandari department of mathematic, ferdowsi university, mashad, iran m. naji midani department of medical physics, mashad university for medical sciences, mashad, iran m. hajizadeh saffar department of medical physics, mashad university for medical sciences, mashad, iran

background: photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of spect images and results to errors in accuracy of quantitative measurements. this can be corrected via different physical or mathematical approaches. as the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘piece wise line...

A. Vahidian Kamyad, M. Hajizadeh Saffar, M. Naji Midani, M.H. Noori Eskandari,

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2003
Chuanyong Bai Paul E Kinahan David Brasse Claude Comtat David W Townsend Carolyn C Meltzer Victor Villemagne Martin Charron Michel Defrise

UNLABELLED There has been considerable debate about the desirability of attenuation correction in whole-body PET oncology imaging. The advantages of attenuation correction are quantitative accuracy, whereas the perceived disadvantages are loss of contrast, noise amplification, and increased scanning time. In this work, we explain contrast changes between images reconstructed with and without at...

Journal: :iranian journal of nuclear medicine 2014
babak fallahi armaghan fard-esfahani arman hassanzadeh-rad alireza emami-ardekani davood beiki

introduction: the main purpose of this study was to compare transient ischemic dilation (tid) ratios in spect-low dose ct and spect myocardial perfusion imaging (mpi) by application of different quantitative programs and quantify the possible shift in the upper normal limits of tid ratio in the spect-ct mpi. methods: 149 patients with low pre-test probability for coronary artery disease (cad),...