نتایج جستجو برای: beam column connection
تعداد نتایج: 281159 فیلتر نتایج به سال:
This study focuses on performance of H-shaped steel beams to CFT column rigid connections. To this end, the effects of internal and external stiffeners on hysteretic behavior of connections were studied. Comparative numerical analyses carried out on eight different connections. To this end finite element models were prepared using ANSYS and nonlinear cyclic analyses carried out. Results of this...
The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection is a T connection representing a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised st...
This paper presents the performance-based optimization of strut-and-tie models in reinforced concrete beam-column connections. The performance-based optimization (PBO) technique is employed to investigate optimal strut-and-tie models in reinforced concrete beam-column connections. Developing strut-and-tie models in reinforced concrete beam-column connections is treated as a topology optimizatio...
the present study is concerned with the simultaneous optimization of the size of components and the arrangement of connections for performance-based seismic design of low-rise spsws. design variables include the size of beams and columns, the thickness of the infill panels, the type of each beam-to-column connection and the type of each infill-to-boundary frame connection. the objective functio...
Moment-resisting frames have extensive usage in earthquake-prone areas and high ability in energy dissipation.After the earthquake in Northridge 1994,Kobe 1995 fixed connections of steel structures have shown poor performance and generally they were caught brittle fracture of beam flange weld to the column.In order to remedy to avoid similar situations in future earthquakes,researchers introduc...
The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection represents a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised steel straps were used...
Steel extended end plate bolted connections are recommended to be widely utilized in special moment-resisting frame subjected to monotonic loading. Improper design of steel beam to column connection can lead to the collapse and fatality of structures. Therefore comprehensive research studies of beam to column connection design should be carried out. Also the performance and effect of corrugated...
Comparing Repaired and Undamaged Specimens Test Results of Post-Tensioned Beam to Column Connections
Since, it is essential to provide homeless people by the earthquake with safe, habitable accommodation repairing medium and slight levels of damage at the connection parts should be undertaken. In order to prove that a repaired connection was sufficiently strong, a precast beam to column post tensioned connection was tested in three phases. In phase one, the middle level damage was observed at ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید