ژورنال: سنجش و ایمنی پرتو 2020

In this study, the MAGIC- f polymer gel was used to determine the absorbed dose by external radiation therapy. The MAGIC- f gel was made under normal pressure and temperature conditions and irradiated with a Siemens 6MV linear accelerator at 10 × 10 cm2 and at a depth of 10 cm. While simulating the head of the accelerator unit by the Monte Carlo method with BEAMnrc code, the percentage depth do...

Hamid Reza Baghani, Seyed Hamid Zoljalali Moghaddam Seyed Rabi Mahdavi

Introduction: The received dose to the surface of tumor bed is one of the main issues in beast intraopeative radiotherapy (IORT). Totally, the administered dose to the surface is usually lower than that of radiotherapy reference point (distal end of tumor bed). Employing a buildup bolus can effectively increase the surface dose and therefore, eliminate such created cold points ...

Gholam Reza Ataei Hamed babapour Mohammad Davoudi

Introduction: Previous studies have shown that a Monte Carlo method for the transportations photon beam in medical linear accelerator is a good way. Strip of simulation can be used to measure the dose distribution in phantoms and patients' body. EGSnrc Code is the only code written for use in the field of radiation therapy that has many subset codes that BEAMnrc code is an impo...

Journal: :Physics in medicine and biology 2010
R Behrens

In April 2005, a geometry package to implement almost arbitrary geometries was added to the EGSnrc code system: egspp (Kawrakow 2005 NRCC Report PIRS-899, Kawrakow and Rogers 2006 NRCC Report PIRS-701). During the use of this geometry package, some inconsistencies were found which might lead to dose values that are wrong by up to a factor of 100. In addition, discrepancies up to a factor of 3 w...

2014
D. MIHAILESCU C. BORCIA D. Mihailescu C. Borcia

In this work, organized as a short review, we present some results obtained by applying the Monte Carlo techniques in the Intra-Operative Radiation Therapy (IORT). The electron beams generated by the NOVAC7 IORT accelerator have been simulated using BEAMnrc/EGSnrc Monte Carlo code, the dose distributions and water-to-air stopping power ratios being later calculated with the associated software ...

2017
Mikaeil Molazadeh Ahad Zeinali Mostafa Robatjazi Alireza Shirazi Ghazale Geraily

This study evaluated the basic dosimetric characteristics of a Dynamic Multi Leaf Collimator (DMLC) using a diode detector and film measurements for Intensity Modulated Radiation Therapy Quality Assurance (IMRT QA). The EGSnrc Monte Carlo (MC) simulation system was used for the determination of MLC characteristics. Radiation transmission and abutting leaf leakage relevant to the LinaTech DMLC H...

Journal: :International Journal of Medical Physics, Clinical Engineering and Radiation Oncology 2016

2009
Laurence E Court David Ching Deborah Schofield Maria Czerminska Aaron M Allen

This study compares Monte Carlo (MC) with conventional treatment planning system (TPS) calculations. The EGS4nrc MC code, BEAMnrc, was commissioned to simulate a Varian 21Ex Linac. The accuracy of the simulations, including points blocked by the jaws, was evaluated by comparing MC with ion chamber and MOSFET measurements. Eight mesothelioma IMRT cases were planned using Eclipse (pencil beam and...

Journal: :iranian journal of medical physics 0
ali shabestani monfared biochemistry and biophysics department, babol university of medical sciences, shahid rajaee oncology hospital, babolsar, iran

introduction superficial x-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (up to 300 kvp). quality of the x-ray beam that can be expressed by half-value layer (hvl), are important indices for this type of treatment effective energy of photon and homogeneity coefficient (hc). materials and methods the hc of the s...