نتایج جستجو برای: bio impedance analysis

تعداد نتایج: 2895096  

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه ارومیه 1377

the methods which are used to analyze microstrip antennas, are divited into three categories: empirical methods, semi-empirical methods and full-wave analysis. empirical and semi-empirical methods are generally based on some fundamental simplifying assumptions about quality of surface current distribution and substrate thickness. thses simplificatioms cause low accuracy in field evaluation. ful...

Journal: :Bio-medical materials and engineering 2014
Xiaoyan Chen Xinqiang Lv Meng Du

The electrode polarization effects on bioelectrical impedance measurement at low-frequency cannot be ignored. In this paper, the bioelectrical data of mice livers are measured to specify the polarization effects on the bio-impedance measurement data. We firstly introduce the measurement system and methodology. Using the depolarization method, the corrected results are obtained. Besides, the spe...

Normal and cancerous tissue have changing values of Electrical Impedance Spectroscopy (EIS). In which with comparing their impedance spectrum with bio-impedance measuring system, they can be used for cancerous tissue diagnosis. Probe is the main part in electrical impedance measurement system. In this paper by employing finite element method EIS factor of mucous tissue derived in 5 different pr...

2013
Seulki Lee Salvatore Polito Carlos Agell Srinjoy Mitra Refet Firat Yazicioglu Jarno Riistama Jörg Habetha Julien Penders

In this paper, we present a new bio-impedance monitor for wearable and continuous monitoring applications. The system consumes less than 14.4mW when measuring impedance, and 0.9mW when idling. Its compact size (4.8cm × 3cm × 2cm) makes it suitable for portable and wearable use. The proposed system has an accuracy of 0.5Ω and resolution of 0.2Ω on both resistance (R) and reactance (X) measuremen...

Journal: :Physiological measurement 2015
B Sanchez E Louarroudi R Pintelon

When stepped-sine impedance spectroscopy measurements are carried out on (periodically) time-varying bio-systems, the inherent time-variant (time-periodic) parts are traditionally ignored or mitigated by filtering. The latter, however, lacks theoretical foundation and, in this paper, it is shown that it only works under certain specific conditions. Besides, we propose an alternative method, bas...

Journal: :iranian journal of basic medical sciences 0
satish kumar department of physiology, yenepoya medical college, deralakatte, mangalore-575018. karnataka, india aswini dutt department of physiology, yenepoya medical college, deralakatte, mangalore-575018. karnataka, india sandhya hemraj department of radiology, yenepoya medical college, deralakatte, mangalore-575018. karnataka, india shankar bhat department of physiology, yenepoya medical college, deralakatte, mangalore-575018. karnataka, india bhat manipadybhima department of physiology, yenepoya medical college, deralakatte, mangalore-575018. karnataka, india

objective(s)bioelectrical impedance is the measure of impedance of the body. impedance consists of electric resistance and reactance. phase angle (pa) is the tan value of the ratio of reactance versus electric resistance. pa depends on cell membrane integrity and on body cell mass. there exists a correlation between pa values and body cell mass.the objective of this study was to compare the pa ...

Aswini Dutt Bhat Manipadybhima Sandhya Hemraj, Satish Kumar, Shankar Bhat

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...

Journal: :Journal of alternative and complementary medicine 2012
Min Soo Kim Young-Chang Cho Suk-Tae Seo Chang-Sick Son Yoon-Nyun Kim

OBJECTIVES A system is being developed for measurement of biologic active points (BAPs) in humans using a modified dry electrode. The BAPs measuring system analyzed the electrical characteristics and searched for the position of BAPs using modified dry electrodes. SUBJECTS Skin electrical resistance at BAPs and non-BAPs was examined with a modified electrode system for healthy male subjects (...

Journal: :Journal of investigative surgery : the official journal of the Academy of Surgical Research 2004
Victor Giurgiutiu Harold Friedman Jonathan Bender Thomas Borg Michael Yost William Newcomb Amanda Black Joel Bost Christopher Stewart

A novel sensor for in situ monitoring of the body reaction to implants has been developed. A piezoelectric wafer active sensor was adapted for biomedical applications (bio-PWAS). A number of bio-PWAS sensors have been implanted in rats and left in place up to 64 days. The bio-PWAS were able to oscillate in several resonance modes, radial-wise (in-plane) and thickness-wise (out-of-plane). The el...

Journal: :International Journal of Advanced Trends in Computer Science and Engineering 2020

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید