نتایج جستجو برای: camera based epid

تعداد نتایج: 2968489  

2013
Alberto Boriano Francesco Lucio Elisa Calamia Elvio Russi Flavio Marchetto

When using an electronic portal imaging device (EPID) for dosimetric verifications, the calibration of the sensitive area is of paramount importance. Two calibration methods are generally adopted: one, empirical, based on an external reference dosimeter or on multiple narrow beam irradiations, and one based on the EPID response simulation. In this paper we present an alternative approach based ...

2015
Pejman Rowshanfarzad Peter Häring Hans L Riis Sune J Zimmermann Martin A Ebert

BACKGROUND In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evalu...

Journal: :Journal of bacteriology 1992
T Kupke S Stevanović H G Sahl F Götz

The plasmid-encoded epidermin biosynthesis gene, epiD, of Staphylococcus epidermidis Tü3298 was expressed in Escherichia coli by using both the malE fusion system and the T7 RNA polymerase-promoter system. EpiD was identified by Western blotting (immunoblotting) with anti-maltose-binding protein (MBP)-EpiD antiserum. EpiD and the MBP-EpiD fusion protein, which were mainly present in the soluble...

Ali Asghar Mowlavi, Azam Afzalifar Mohammad Mohammadi, Sara Abdollahi

Introduction: The accuracy of patient positioning plays an important role for radiotherapy tasks. Short and automated Quality Assurance (QA) programs are becoming one of the challenging tasks in Radiotherapy. The current study, investigates the accuracy of treatment couch positioning with four degrees of freedom (4DoF) using a fast and accurate method based on an image acquired...

2016
Mukhtar Alshanqity Andrew Nisbet

The majority of EPID dosimetry literature discusses response linearity and the so-called image lag and ghosting effects despite the lack of a common definition of these quantities. However, the results of these studies are generally not consistent, and it is often difficult to compare the results from different studies. We present here a detailed study of the acquisition and readout characteris...

2016
Iori Sumida Hajime Yamaguchi Indra J. Das Hisao Kizaki Keiko Aboshi Mari Tsujii Yuji Yamada Osamu Suzuki Yuji Seo Fumiaki Isohashi Kazuhiko Ogawa

Patient-specific quality assurance for intensity-modulated radiation therapy (IMRT) dose verification is essential. The aim of this study is to provide a new method based on the relative error distribution by comparing the fluence map from the treatment planning system (TPS) and the incident fluence deconvolved from the electronic portal imaging device (EPID) images. This method is validated fo...

2014
Pejman Rowshanfarzad Conor K McGarry Michael P Barnes Mahsheed Sabet Martin A Ebert

BACKGROUND In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of en...

2013
B Mijnheer I Olaciregui-Ruiz R Rozendaal J-J Sonke H Spreeuw R Tielenburg M van Herk Antoni van Leeuwenhoek

In this paper the various approaches of EPID-based in vivo IMRT and VMAT dose verification, and their clinical implementation, are described. It will be shown that EPID-based in vivo dosimetry plays an important role in the total chain of verification procedures in a radiotherapy department. EPID-based dosimetry, in combination with in-room imaging, is a fast and accurate tool for 3D in vivo ve...

Journal: :Medical physics 2006
L N McDermott M Wendling B van Asselen J Stroom J J Sonke M van Herk B J Mijnheer

The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routine pre-treatment dosimetry in our clinic. Furthermore, we described how EPID dosimetry was used to solve a clinical problem. IMRT prostate plans were delivered to a homogeneous slab phantom. EPID transit images w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید