نتایج جستجو برای: collimator

تعداد نتایج: 2952  

2002
Peter Tenenbaum

We summarize the formalism of collimator wakefields and their effect on beams that are near the center of the collimator gap, and apply the formalism to the TESLA, NLC, and CLIC collimation systems. Collimator Wakefield Calculations for ILC-TRC Report

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2015
Casper Beijst Mattijs Elschot Max A Viergever Hugo W A M de Jong

UNLABELLED In SPECT using high-energy photon-emitting isotopes, such as (131)I, parallel-hole collimators with thick septa are required to limit septal penetration, at the cost of sensitivity and resolution. This study investigated a parallel-hole collimator with cone-shaped holes, which was designed to limit collimator penetration while preserving resolution and sensitivity. The objective was ...

Journal: :Annals of nuclear medicine 2006
Nobutoku Motomura Kyojiro Nambu Akihiro Kojima Seiji Tomiguchi Koichi Ogawa

Due to the collimator aperture, spatial resolution of SPECT data varies with source-to-detector distance. Since the radius of detector rotation is bigger when scanning larger patients, spatial resolution is degraded in these cases. Emitted gamma rays travel not only along the central axis of the collimator hole but also off-axis due to the collimator aperture. However, an off-axis ray at one an...

2010
Tarek Halabi Bruce Faddegon

We design a practical procedure for measuring translational and rotational misalignment of graticule with collimator axis of rotation and collimator jaws, respectively. The procedure's quantitative results are accurate to less than 0.2 mm (at isocenter) and do not assume alignment of radiation focal spot with collimator axis of rotation. When provided with these quantitative results, the manufa...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1988
R J Jaszczak K L Greer R E Coleman

A specially designed high resolution converging collimator having a focal length of 50 cm has been evaluated for cone beam single photon emission computed tomography (SPECT). The focal region was investigated by imaging a point source placed at the expected focal point and along the central ray of the collimator in front of and behind the focal point. Technetium-99m point source sensitivities m...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1986
B M Tsui G T Gullberg E R Edgerton D R Gilland J R Perry W H McCartney

A long bore fan beam collimator for imaging the head was designed and constructed for a SPECT system with a rotating scintillation camera. In order to avoid the patient's shoulder during rotation of the camera with a thick camera housing, the long bore design is necessary to allow the collimator to get close to the patient's head for improved spatial resolution. Operating at the minimum radius ...

Journal: :Journal of nuclear medicine technology 2006
Hiroyuki Tsushima Teruhiko Takayama Takashi Yamanaga Hiroto Kizu Yoshihiro Shimonishi Kazuhisa Kosakai Atsushi Noguchi Masahisa Onoguchi

UNLABELLED This study was performed to investigate the usefulness of a general-purpose medium-energy (ME) collimator for the accurate localization of the sentinel lymph node (SLN) in breast cancer patients. METHODS We compared phantom images and lymphoscintigraphy images obtained under different conditions for a patient with breast cancer. Comparisons were performed between 2 cameras, between...

Journal: :iranian journal of nuclear medicine 0
alireza sadremomtaz department of physics, faculty of science, university of guilan, rasht, iran zeinab telikani department of physics, faculty of science, university of guilan, rasht, iran

introduction: image quality and accuracy of in vivo activity quantification in spect are affected by collimator penetration and scatter components, especially in high energy imaging. these phenomena highly depend on the collimator characteristic and photon energy. the presence of penetrated and scattered photons from collimator in spect images degrades spatial resolution, contrast and image qua...

2008
André Sopczak

The importance of collimator R&D with test beam facilities is demonstrated with the example of ILC collimator studies at SLAC End Station A. Related LHC collimator aspects and longer term plans are addressed. Presented at IDTB07, ILC Detector Test Beam workshop, Fermilab, USA, 2007.

Journal: :Journal of radiation research 2001
M Ishikawa T Kobayashi Y Sakurai K Kanda

Because background radiation in an irradiation room creates a problem with the PG-SPECT (Prompt Gamma-ray Single Photon Emission Computed Tomography) system, which evaluates the absorbed dose for the Boron Neutron Capture Therapy treatment, optimization of a collimator system was performed while taking the shielding of background gamma-rays into consideration. Assuming that a parallel-beam coll...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید