نتایج جستجو برای: cross calibration

تعداد نتایج: 543673  

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2002
Lilli Geworski Bernd O Knoop Maike de Wit Velimir Ivancević Roland Bares Dieter L Munz

UNLABELLED The purpose of this study was to compare the calibration of PET scanners and their cross calibration to peripheral devices in a multicenter study. METHODS Twenty-three dedicated PET scanners were investigated, applying standardized protocols. To ensure exact determination of the activity used, dose calibrators were checked using (68)Ge standards. RESULTS Nine of 19 and 11 of 20 s...

Journal: :Remote Sensing 2017
Yepei Chen Kaimin Sun Deren Li Ting Bai Chengquan Huang

Earth observation data obtained from remote sensors must undergo radiometric calibration before use in quantitative applications. However, the large view angles of the panchromatic multispectral sensor (PMS) aboard the GF-4 satellite pose challenges for cross-calibration due to the effects of atmospheric radiation transfer and the bidirectional reflectance distribution function (BRDF). To addre...

Journal: :Journal of the Japan Society for Precision Engineering, Contributed Papers 2006

2012
Kirsten Bacia Zdeněk Petrášek Petra Schwille

Dual-color fluorescence cross-correlation spectroscopy (dcFCCS) allows one to quantitatively assess the interactions of mobile molecules labeled with distinct fluorophores. The technique is widely applied to both reconstituted and live-cell biological systems. A major drawback of dcFCCS is the risk of an artifactual false-positive or overestimated cross-correlation amplitude arising from spectr...

Journal: :Remote Sensing 2014
Zhengchao Chen Bing Zhang Hao Zhang Wenjuan Zhang

For on-orbit calibration of the Beijing-1 multispectral imagers (Beijing-1/MS), a field calibration campaign was performed at the Dunhuang calibration site during September and October of 2008. Based on the in situ data and images from Beijing-1 and Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), three vicarious calibration methods (i.e., reflectance-based, irradiance-based, and cr...

Journal: :Journal of analytical toxicology 2001
T C Whiting R H Liu W T Chang M R Bodapati

In order to achieve accurate quantitation of drugs and metabolites (analytes) in complex matrices, 2H- (and less commonly 13C-) labeled analogues of the analytes are now routinely adapted as the internal standards (IS) using linear calibration models to fit data generated by selected ion monitoring gas chromatography-mass spectrometry (GC-MS) protocols. In this study, the effects of cross-contr...

2009
M. Aksoy C. Forman M. Straka S. J. Holdsworth S. T. Skare J. Hornegger R. Bammer

INTRODUCTION – Utilization of stereovision [1,2] or monovision [3] systems have been suggested as a way to perform rigid head motion correction for MRI. Since no additional MR-based navigator acquisition is required, these systems can be used with any scanning protocol with only minimal changes to the sequence. However, the usability of optical systems in clinical practice has so far been limit...

2015
J. McCorkel

Introduction Conclusions References Tables Figures

2017
Mingjun Deng Guo Zhang Ruishan Zhao Shaoning Li Jiansong Li

The Chinese Gaofen-3 (GF-3) mission was launched in August 2016, equipped with a full polarimetric synthetic aperture radar (SAR) sensor in the C-band, with a resolution of up to 1 m. The absolute positioning accuracy of GF-3 is of great importance, and in-orbit geometric calibration is a key technology for improving absolute positioning accuracy. Conventional geometric calibration is used to a...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید