نتایج جستجو برای: czt detector

تعداد نتایج: 58904  

Journal: :Medical physics 2011
Charlotte Robert Guillaume Montémont Véronique Rebuffel Loïck Verger Irène Buvat

PURPOSE Small field-of-view CdZnTe (CZT) gamma cameras are increasingly studied for breast lesion detection to complement mammography or ultrasonographic findings. However, in classical collimation configurations, they remain limited by the trade-off between spatial resolution and sensitivity. The HiSens architecture was proposed to overcome these limitations. Using an accurate 3D localization ...

2017
K Larson V T. Jordanov Mark L. McConnell J R. Macri James Ryan Valentin T. Jordanov Olivier Tousignant K. Larson V. Jordanov M. L. McConnell O. Tousignant

We present the requirements, design, and performance of an analog circuit for processing the noncollecting anode strip signals from a cadmium zinc telluride (CZT) strip detector with orthogonal coplanar anodes. Detector signal simulations and measurements with a prototype are used to define the range of signal characteristics as a function of location of the gamma interaction in the detector. T...

2006
J. Hong J. E. Grindlay N. Chammas A. Copete R. G. Baker S. D. Barthelmy N. Gehrels W. R. Cook J. A. Burnham F. A. Harrison J. Collins W. W. Craig

We describe the detector development for a balloon-borne wide-field hard X-ray (20 – 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT dete...

2011

This pathway describes the development of soft gamma-ray/hard x-ray detector arrays at NASA’s Goddard Space Flight Center (GSFC, or Goddard), through a collaboration between the gamma-ray spectroscopy group and the detector branch. The Cadmium Zinc Telluride (CdZnTe, or CZT) detectors which resulted from this decade-long development were first flown on the wildly successful SWIFT mission in 200...

1998
P. F. BLOSER T. NARITA J. E. GRINDLAY K. SHAH

We describe initial results of our program to develop and test Cd-Zn-Te (CZT) detectors with a pixellated array readout. Our primary interest is in the development of relatively thick CZT detectors for use in astrophysical coded aperture telescopes with response extending over the energy range ∼ 10 − 600 keV. The coded aperture imaging configuration requires only relatively large area pixels (1...

Jalil Pirayesh Islamian, Parvaneh Darkhor Samira Abbaspour

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2016
Rene Nkoulou Tobias A Fuchs Aju P Pazhenkottil Silke M Kuest Jelena R Ghadri Julia Stehli Michael Fiechter Bernhard A Herzog Oliver Gaemperli Ronny R Buechel Philipp A Kaufmann

Recent advances in SPECT technology including cadmium-zinc-telluride (CZT) semiconductor detector material may pave the way for absolute myocardial blood flow (MBF) measurements by SPECT. The aim of the present study was to compare K1 uptake rate constants as surrogates of absolute MBF and myocardial flow reserve index (MFRi) in humans as assessed with a CZT SPECT camera versus PET. METHODS A...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2010
Bernhard A Herzog Ronny R Buechel Ruth Katz Michael Brueckner Lars Husmann Irene A Burger Aju P Pazhenkottil Ines Valenta Oliver Gaemperli Valerie Treyer Philipp A Kaufmann

UNLABELLED We aimed at establishing the optimal scan time for nuclear myocardial perfusion imaging (MPI) on an ultrafast cardiac gamma-camera using a novel cadmium-zinc-telluride (CZT) solid-state detector technology. METHODS Twenty patients (17 male; BMI range, 21.7-35.5 kg/m(2)) underwent 1-d (99m)Tc-tetrofosmin adenosine stress and rest MPI protocols, each with a 15-min acquisition on a st...

2006
A. Garson

One of the key aspects of a detector material for space-borne hard X-ray and gamma-ray telescopes is the rate of prompt and delayed background events generated inside the material by charged and neutral particles striking the detector. These particles are Cosmic Rays, particles trapped in Earth’s magnetic field, and secondaries from Cosmic Ray interacting with the atmosphere and the spacecraft....

Journal: :Journal of Nuclear Science and Technology 2008

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید