PURPOSE This study aimed to provide comparative measurements of the effective dose from direct and indirect digital panoramic units according to phantoms and exposure parameters. MATERIALS AND METHODS Dose measurements were carried out using a head phantom representing an average man (175 cm tall, 73.5 kg male) and a limbless whole body phantom representing an average woman (155 cm tall, 50 k...
orthopantomography is a well-established imaging technique in dental diagnosis. although its exposure to individuals is relatively low compared to other diagnostic radiology examinations, it is still the most frequent x-ray examination. so it is important to estimate absorbed dose to critical organs in this examination. the present study was designed to determine the radiation doses to eyes, pa...
introduction: in diagnostic and therapeutic procedures, dosimetric studies are performed on the dosimetric systems in order to comply the radiation safety standards. monte carlo methods are used due to the high complexity and cost of patient-specific phantom construction. the high complexity of the digitized phantoms greatly increases the time and computational task of the monte carlo calculati...
The present study was performed to determine the potential of applying dual-energy subtraction (DES) digital tomosynthesis to basic physical evaluations. Volumetric X-ray DES digital tomosysnthesis was used to obtain an image of a detectability phantom (an artificial lesion). The image quality of DES digital tomosynthesis was compared to that of DES radiography. The purpose of this study was to...
PURPOSE Develop a technique to fabricate a 3D anthropomorphic breast phantom with known ground truth for image quality assessment of 2D and 3D breast x-ray imaging systems. METHODS The phantom design is based on an existing computer model that can generate breast voxel phantoms of varying composition, size, and shape. The physical phantom is produced in two steps. First, the portion of the vo...
BACKGROUND AND PURPOSE Compared to cone-beam computed tomography, digital tomosynthesis imaging has the benefits of shorter scanning time, less imaging dose, and better mechanical clearance for tumor localization in radiation therapy. However, for lung tumors, the localization accuracy of the conventional digital tomosynthesis technique is affected by the lack of depth information and the exist...
PURPOSE To compare the contrast-detail (CD) characteristics of screen-film (SF) and postprocessed digital images by using a phantom-based method. MATERIALS AND METHODS Images of a CD phantom with polymerized methyl methacrylate were acquired with SF and full-field digital mammography systems at matched exposure conditions. A four-alternative forced-choice experiment was conducted with seven o...
A questionnaire survey about mammography in Hokkaido was mailed to 121 facilities from August to September 2009. We surveyed the conditions of digital mammography with regard to quality control (QC) and average glandular dose at 79 facilities in Hokkaido in 2009, and the results of the survey were compared with those of 2004. We found that digital mammography techniques were widely used across ...
Introduction: In diagnostic and therapeutic procedures, dosimetric studies are performed on the dosimetric systems in order to comply the radiation safety standards. Monte Carlo methods are used due to the high complexity and cost of patient-specific phantom construction. The high complexity of the digitized phantoms greatly increases the time and computational task of the Monte Carlo calculati...