Journal: :iranian journal of radiation research 0
m. allahverdi department of medical physics, tehran university of medical sciences, tehran, iran gh. geraily department of medical physics, tehran university of medical sciences, tehran, iran m. esfehani departments of radiology, iran university of medical sciences, tehran, iran a. sharafi department of radiotherapy and oncology, cancer institute, tehran university of medical sciences, tehran, iran a. shirazi department of medical physics, tehran university of medical sciences, tehran, iran

background: total body irradiation (tbi) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under tbi treatment. diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. the aim of this study was to describe the measurements made to calibrate diod...

Journal: :Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2010
Vladimir Feygelman D Opp K Javedan A J Saini G Zhang

The Delta4 biplanar diode array dosimeter was validated for helical tomotherapy delivery QA. The basic detector characteristics were found to be satisfactory in terms of short-term reproducibility (0.1%), linearity (<0.1%), dose rate dependence (0.4%), and absolute calibration accuracy (0.4% in the center of the phantom compared with the independently calibrated diode). Relative calibration of ...

Journal: :Medical physics 2013
Jonathan Morin Dominic Beliveau-Nadeau Eunah Chung Jan Seuntjens Dany Theriault Louis Archambault Sam Beddar Luc Beaulieu

PURPOSE Small-field dosimetry is challenging, and the main limitations of most dosimeters are insufficient spatial resolution, water nonequivalence, and energy dependence. The purpose of this study was to compare plastic scintillation detectors (PSDs) to several commercial stereotactic dosimeters by measuring total scatter factors and dose profiles on a CyberKnife system. METHODS Two PSDs wer...

2016
Madelaine K. Tyler Paul Z.Y. Liu Christopher Lee David R. McKenzie Natalka Suchowerska

Flattening filter-free (FFF) beams are becoming the preferred beam type for stereotactic radiosurgery (SRS) and stereotactic ablative radiation therapy (SABR), as they enable an increase in dose rate and a decrease in treatment time. This work assesses the effects of the flattening filter on small field output factors for 6 MV beams generated by both Elekta and Varian linear accelerators, and d...

2000
X. R. Zhu

Silicon diode dosimeters have been used routinely for in-vivo dosimetry. Despite their popularity, an appropriate implementation of an in-vivo dosimetry program using diode detectors remains a challenge for clinical physicists. One common approach is to relate the diode readout to the entrance dose, that is, dose to the reference depth of maximum dose such as d(max) for the 10x10 cm(2) field. V...

Journal: :Physics in medicine and biology 2001
T Cheung M Butson P K Yu

Dosimetry of blood irradiation using x-ray beams on a medical linear accelerator has been studied to evaluate the accuracy of a diode detector and the delivery achievable. Variations in applied doses for a standard dual field 6 MV x-ray are measured with a commercial diode detector. Results show that the diode detector measured applied in vitro doses to within 5.4% (2 standard deviations (2 SD)...

ژورنال: سنجش و ایمنی پرتو 2016

Knowing patient exact dose during radiological activities is considered as one of the main principles to decrease radiation-induced dangers which are not really necessary and affect a great deal of people. In this respect, in recent years many extensive studies have been done on types of photodiodes and production of X-ray detectors using semiconductor elements. Since these elements are not ver...

Journal: :Brazilian Journal of Radiation Sciences 2022

The growing interest in low-dose (&lt; 100 Gy) radiation processing applications has raised concerns about accurately measuring the absorbed dose irradiated materials. Depending on irradiator design, transit time due to radioactive source movement (or product itself) until stable irradiation position might affect predicted dose. This work aims evaluate a 60Co Gammacell 220-Nordion irradiator, w...

Journal: :Medical physics 2012
S Tanny B Gautam D Pearson E Parsai

PURPOSE Solid state detectors from two independent systems have shown similar over-responses to small electron fields used for treatment of surface lesions. We propose to evaluate the accuracy of solid state detector systems for highly blocked electron fields as a method for clinical dosimetry and determine the cause for any deviations from expected dose-delivery calculations. METHODS A QED D...