نتایج جستجو برای: dose distribution flatbed scanner monte carlo radiochromic film dosimetry

تعداد نتایج: 1069545  

Journal: :Journal of radiation research 2012
Katsumi Shima Kunihiko Tateoka Yuichi Saitoh Junji Suzuki Yuji Yaegashi Kazunori Fujimoto Takuya Nakazawa Akihiro Nakata Tadanori Abe Sho Imai Kouichi Sakata Masato Hareyama

The post-exposure density growth (PEDG) is one of the characteristics of radiochromic film (RCF). In film dosimetry using RCF and a flatbed scanner, pixel values read out from the RCF are converted to dose (hereafter, film dose) by using a calibration curve. The aim of this study is to analyze the relationship between the pixel value read out from the RCF and the PEDG, and that between the film...

Journal: :East European journal of physics 2022

The article provides a sequence of steps for using RISØ calorimeters calibration and subsequent use B3 radiochromic film dosimeters (GEX corporation) scanner measuring absorbed doses. Calibration was carried out with the help electron beam accelerator in range doses 3 – 40 kGy (measurement calorimeters). In course work, following out: dosimetry films calorimeters; plotting curve dosimetric film...

2013
Masao Tanooka Hiroshi Doi Hideharu Miura Hiroyuki Inoue Yasue Niwa Yasuhiro Takada Masayuki Fujiwara Toshiyuki Sakai Kiyoshi Sakamoto Norihiko Kamikonya Shozo Hirota

We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic...

Journal: :European journal of radiology 2008
Scott D Oves Kenneth R Hogstrom Kyungmin Ham Erno Sajo Joseph P Dugas

The purpose of this study was to compare dose measurements using ion chamber and radiochromic film dosimetry for a 35-keV synchrotron beam useful for Auger electron therapy. A 1.3-GeV electron beam, transported through a 3-pole superconducting wiggler magnet, produced a polychromatic photon beam from which a 35-keV beam (3.3 mm Al HVL) was selected using a monochromator. A 2.8 cm x 2.5 cm field...

2008
Hiroko Ohuchi Mitsuya Abe

Gafchromic XRCT radiochromic film is a self-developing high sensitivity radiochromic film product which can be used for assessment of delivered radiation doses which could match applications such as computed tomography (CT) dosimetry. The film automatically changes color upon irradiation changing from amber to dark greenish-black depending on the level of exposure. The absorption spectra of Gaf...

Journal: :Medical physics 2009
Slobodan Devic Nada Tomic Christopher G Soares Ervin B Podgorsak

The authors present a radiochromic film dosimetry protocol for a multicolor channel radiochromic film dosimetry system consisting of the external beam therapy (EBT) model GAFCHROMIC film and the Epson Expression 1680 flat-bed document scanner. Instead of extracting only the red color channel, the authors are using all three color channels in the absorption spectrum of the EBT film to extend the...

2010
Heeteak Chung Bart Lynch Sanjiv Samant

To report a study of the use of GAFCHROMIC EBT radiochromic film (RCF) digitized with a commercially available flatbed document scanner for accurate and reliable all-purpose two-dimensional (2D) absolute dosimetry within a clinical environment. We used a simplified methodology that yields high-precision dosimetry measurements without significant postirradiation correction. The Epson Expression ...

2012
Naoki Hayashi Yoichi Watanabe Ryan Malmin Hideki Kato

The purpose of this study was to evaluate the triple channel correction acquisition (TCCA) method for radiochromic film dosimetry performed with a flatbed scanner. The study had two parts: a fundamental and a clinical examination. In the fundamental examination, we evaluated the accuracy of calibration curves for Gafchromic EBT2 (EBT2). The films were calibrated using a field-by-field method wi...

2007
Martina Fuss Eva Sturtewagen Carlos De Wagter Dietmar Georg

The suitability of radiochromic EBT film was studied for high-precision clinical quality assurance (QA) by identifying the dose response for a wide range of irradiation parameters typically modified in highly-conformal treatment techniques. In addition, uncertainties associated with varying irradiation conditions were determined. EBT can be used for dose assessment of absorbed dose levels as we...

Journal: :Physics in medicine and biology 2009
G Massillon-Jl R Minniti M G Mitch M J Maryanski C G Soares

Absorbed dose distributions in 3D imparted by a single (90)Sr/(90)Y beta particle seed source of the type used for intravascular brachytherapy were investigated. A polymer gel dosimetry medium was used as a dosemeter and phantom, while a special high-resolution laser CT scanner with a spatial resolution of 100 microm in all dimensions was used to quantify the data. We have measured the radial d...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید