نتایج جستجو برای: drug eluting stents

تعداد نتایج: 601316  

2013
Sripal Bangalore Bora Toklu Mario Fusaro Edward L Hannan

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

Journal: :The New England journal of medicine 2010
Christoph Kaiser Soeren Galatius Paul Erne Franz Eberli Hannes Alber Hans Rickli Giovanni Pedrazzini Burkhard Hornig Osmund Bertel Piero Bonetti Stefano De Servi Hans-Peter Brunner-La Rocca Ingrid Ricard Matthias Pfisterer

BACKGROUND Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether this increase in risk was also seen with second-generation drug-eluting stents. METHOD...

2012
Jacob C Townsend Phillip Rideout Daniel H Steinberg

Bare metal stents have a proven safety record, but limited long-term efficacy due to in-stent restenosis. First-generation drug-eluting stents successfully countered the restenosis rate, but were hampered by concerns about their long-term safety. Second generation drug-eluting stents have combined the low restenosis rate of the first generation with improved long-term safety. We review the evol...

Journal: :Coronary artery disease 2008
Shyam Poludasu Erdal Cavusoglu Waqas Khan Jonathan D Marmur

BACKGROUND Recent studies have questioned the safety of drug-eluting stents because of a higher incidence of late stent thrombosis, raising the possibility that drug-eluting stents may be associated with an increased mortality. The effect of drug-eluting stents on mortality in African-Americans is unknown. METHODS We evaluated 628 African-American patients (354 patients treated with drug-elut...

Journal: :Circulation 2009
Yan Li Zhe Zheng Bo Xu Shiju Zhang Wei Li Runlin Gao Shengshou Hu

BACKGROUND Numerous studies have compared the outcomes of coronary artery bypass grafting (CABG) surgery and coronary stenting for the treatment of multivessel coronary disease. In 2003, drug-eluting stents were introduced with the hope of reducing restenosis. However, limited information exists on the comparison of drug-eluting stents and CABG surgery. The long-term outcome of drug-eluting ste...

Journal: :The New England journal of medicine 2008
Oscar C Marroquin Faith Selzer Suresh R Mulukutla David O Williams Helen A Vlachos Robert L Wilensky Jean-François Tanguay Elizabeth M Holper J Dawn Abbott Joon S Lee Conrad Smith William D Anderson Sheryl F Kelsey Kevin E Kip

BACKGROUND Recent reports suggest that off-label use of drug-eluting stents is associated with an increased incidence of adverse events. Whether the use of bare-metal stents would yield different results is unknown. METHODS We analyzed data from 6551 patients in the National Heart, Lung, and Blood Institute Dynamic Registry according to whether they were treated with drug-eluting stents or ba...

Journal: :Circulation 2005
Aloke V Finn Frank D Kolodgie Jan Harnek L J Guerrero Eduardo Acampado Kirubel Tefera Kristi Skorija Deena K Weber Herman K Gold Renu Virmani

BACKGROUND Although effective coverage of challenging coronary lesions has warranted the use of overlapping drug-eluting stents, the histopathological response to stent overlap is unknown. METHODS AND RESULTS The arterial reaction to overlapping Cypher or Taxus drug-eluting stents was examined in rabbits with bare metal stents, BxVelocity or Express, serving as controls. Single iliac artery b...

Journal: :The American journal of medicine 2009
Henri Roukoz Anthony A Bavry Michael L Sarkees Girish R Mood Dharam J Kumbhani Mark G Rabbat Deepak L Bhatt

BACKGROUND Several observational reports have documented both increased and decreased cardiac mortality or Q-wave myocardial infarction with drug-eluting stents compared with bare-metal stents. METHODS We sought to evaluate the safety and efficacy of drug-eluting stents compared with bare-metal stents early after intervention (<1 year) and late (>1 year) among a broad population of patients, ...

Journal: :The New England journal of medicine 2016
Eric R Bates

BACKGROUND Limited data are available on the long-term effects of contemporary drug-eluting stents versus contemporary bare-metal stents on rates of death, myocardial infarction, repeat revascularization, and stent thrombosis and on quality of life. METHODS We randomly assigned 9013 patients who had stable or unstable coronary artery disease to undergo percutaneous coronary intervention (PCI)...

Journal: :Revista espanola de cardiologia 2013
Takashi Muramatsu Yoshinobu Onuma Yao-Jun Zhang Christos V Bourantas Alexander Kharlamov Roberto Diletti Vasim Farooq Bill D Gogas Scot Garg Hector M García-García Yukio Ozaki Patrick W Serruys

First generation drug-eluting stents have considerably reduced in-stent restenosis and broadened the applications of percutaneous coronary interventions for the treatment of coronary artery disease. The polymer is an integral part of drug-eluting stents in that, it controls the release of an antiproliferative drug. The main safety concern of first generation drug-eluting stents with permanent p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید