This paper proposes a novel combined device for fault current limiting and dynamic voltage restoring. It consists of a diode bridge superconducting fault current limiter and a dynamic voltage restorer, which both connected together via a common dc link. Interline FCL-DVR system is interlined between two different feeders that connected to a point of common coupling (PCC) in distribution network...
This paper presents the design of a Superconducting Fault Current Limiter (SFCL) and calculation results forces stresses in windings resistive fault current limiter. The limiter consists two parallelly connected magnetically coupled windings, cooled by single stage cryocooler. Magnetically compensated made HTS tape give very low voltage on at nominal current. Limitation short-circuit time value...
The design process of a superconducting current limiter (SFCL) requires simulation and definition of its electrical, magnetic and thermal properties in form of equivalent circuits and mathematical models. However, any change in SFCL parameters: dimension, resistance, and operating temperature can affect the limiting mode, quench time, and restore time. In this paper, following the simulation of...
This paper presents the analysis, design, construction and ac test results of low voltage single-phase resistive superconductor electrical current limiters. Two different types of resistive superconductor current limiter are presented: the first one is built with three concentric, cylindrical and helicoidal coils connected in parallel and the second one is built with two superposed cylindrical ...
superconductor fault current limiter (sfcl) is an effective device to suppress high fault currents. this paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. appropriate location and type of the limiters in a hv substation is selected by a qualitative approach based on the equal area criterion. study system is simulated by...
in this paper, the impacts of installing superconducting fault current limiter (sfcl)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (dg). among various sfcls, the hybrid type with a superconducting element in parallel with a current limiting reactor (clr) is selected. this is more effective than resisto...