Journal: :Journal of Applied Clinical Medical Physics 2000

Ali Asghar Mowlavi, Azam Afzalifar Mohammad Mohammadi, Sara Abdollahi

Introduction: The accuracy of patient positioning plays an important role for radiotherapy tasks. Short and automated Quality Assurance (QA) programs are becoming one of the challenging tasks in Radiotherapy. The current study, investigates the accuracy of treatment couch positioning with four degrees of freedom (4DoF) using a fast and accurate method based on an image acquired...

Journal: :iranian journal of radiation research 0
s. r. mahdavi medical physics department of iran university of medical sciences, tehran, iran e. jazayeri gharehbagh department of radiology and radiotherapy technology, school of allied health sciences, tehran university of medical sciences, tehran, iran b. mofid 3radiotherapy department of shahid beheshti university of medical sciences, tehran, iran a. h. jafari research center of biomedical technology and robotics, tehran university of medial sciences, tehran, iran a. r. nikoofar radiotherapy department of iran university of medical sciences, tehran, iran

background: to correct patient positioning errors (setup errors) during prostate cancer treatment using epid and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. materials and methods: fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field imrt planning technique. the p...

2014
Birendra Kumar Birendra Kumar Rout Chandra Shekar Alok Kumar Kondapalli Kesava Durga Ramesh

Journal: :Journal of Applied Clinical Medical Physics 2011

Journal: :Physics in medicine and biology 2002
Larry E Antonuk

A review of electronic portal imaging devices (EPIDs) used in external beam, megavoltage radiation therapy is presented. The review consists of a brief introduction to the definition, role and clinical significance of portal imaging, along with a discussion of radiotherapy film systems and the motivations for EPIDs. This is followed by a summary of the challenges and constraints inherent to por...

2001
Martin Lachaine Biagio Gino Fallone

During a radiation therapy treatment, many factors may influence the proper delivery of a calculated dose distribution. Some of these factors include misalignment of the treatment beam with respect to the patient, external or internal patient motion, or inaccurate positioning of beam-modifying devices.1 In order to quantify these geometric inaccuracies during treatment, a portal image is typica...