Journal: :Juntendo Medical Journal 2022

Objectives To develop a method for detecting jaw positions during jaw-tracking delivery to ensure an accurate of radiation patients using electronic portal imaging device (EPID) in the cine mode on linear accelerator radiotherapy.

Journal: :iranian journal of radiation research 0
m.a. mosleh-shirazi department of radiotherapy, namazi hospital, shiraz university of medical sciences, shiraz, iran h. taylor department of radiotherapy, royal marsden hospital, sutton, surrey, uk a.p. warrington joint department of physics, royal marsden hospital and institute of cancer research, sutton, surrey, uk f.h. saran department of radiotherapy, royal marsden hospital, sutton, surrey, uk

background: in order to assign appropriate planning target volume (ptv) margins, each centre should measure the patient positioning deviations for their set-up techniques. at the royal marsden hospital, uk, a conformal shell (cast) system is used when a stereotactic frame is not suitable. in this paper, we report on a series of measurements with the aim of obtaining the systematic and random co...

Ali Asghar Mowlavi, Azam Afzalifar Mohammad Mohammadi, Sara Abdollahi

Introduction: The accuracy of patient positioning plays an important role for radiotherapy tasks. Short and automated Quality Assurance (QA) programs are becoming one of the challenging tasks in Radiotherapy. The current study, investigates the accuracy of treatment couch positioning with four degrees of freedom (4DoF) using a fast and accurate method based on an image acquired...

Journal: :iranian journal of radiation research 0
s. rabie mahdavi department of medical physics, babol university of medical sciences, babol, iran a. shirazi department of biophysics, faculty of medicine, tehran university of medical sciences, tehran, iran d. sardari department of biophysics, faculty of medicine, tehran university of medical sciences, tehran, iran l. sadri azad research and science university, tehran, iran

abstractbackground: delivering the radiation dose to the target volume and minimizing the dose to normal tissues are the main objectives in radiotherapy. the aim of our study is to enhance the contrast of the portal image to increase the accuracy of delineation of the organs in the irradiation field.   methods: the software was written based on local enhancement of the pixel values in image mat...

F Shahedi, H Gholamhosseinian M H Bahreyni M Mohammadi, M Momennezhad, R Salek, S Bayani, S M Hashemi, S Nasseri

Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study, first, the EPID calibration curve and correction coefficients for field size were obtained from EPID and ionization chamber. Second, the...

Hajareh Ghaderzadeh Hamed Ghaffari Mahdieh Afkhami, Mohammad Haghparast Seyed Rabi Mahdavi

Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...