نتایج جستجو برای: etco2

تعداد نتایج: 362  

2017
Nicolas Segal Anja K Metzger Johanna C. Moore Laura India Michael C. Lick Paul S. Berger Wanchun Tang David G. Benditt Keith G. Lurie

Amplitude Spectrum Area (AMSA) values during ventricular fibrillation (VF) correlate with myocardial energy stores and predict defibrillation success. By contrast, end tidal CO2 (ETCO2) values provide a noninvasive assessment of coronary perfusion pressure and myocardial perfusion during cardiopulmonary resuscitation (CPR). Given the importance of the timing of defibrillation shock delivery on ...

Journal: :Prehospital and disaster medicine 2013
Christopher J Cooper James J Kraatz David S Kubiak James W Kessel Stephen L Barnes

INTRODUCTION End tidal CO2 (ETCO2) has been established as a standard for confirmation of an airway, but its role is expanding. In certain settings ETCO2 closely approximates the partial pressure of arterial CO2 (PaCO2) and has been described as a tool to optimize a patient's ventilatory status. ETCO2 monitors are increasingly being used by EMS personnel to guide ventilation in the prehospital ...

Journal: :Academic emergency medicine : official journal of the Society for Academic Emergency Medicine 2006
John H Burton John D Harrah Carl A Germann Douglas C Dillon

OBJECTIVES The value of ventilation monitoring with end-tidal carbon dioxide (ETCO2) to anticipate acute respiratory events during emergency department (ED) procedural sedation and analgesia (PSA) is unclear. The authors sought to determine if ETCO2 monitoring would reveal findings indicating an acute respiratory event earlier than indicated by current monitoring practices. METHODS The study ...

Journal: :Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors 2016
Ryan A Murphy Bentley J Bobrow Daniel W Spaite Chengcheng Hu Robyn McDannold Tyler F Vadeboncoeur

INTRODUCTION International Guidelines recommend measurement of end-tidal carbon dioxide (EtCO2) to enhance cardiopulmonary resuscitation (CPR) quality and optimize blood flow during CPR. Numerous factors impact EtCO2 (e.g., ventilation, metabolism, cardiac output), yet few clinical studies have correlated CPR quality and EtCO2 during actual out-of-hospital cardiac arrest (OHCA) resuscitations. ...

توتونچی, محمدضیاء, حسنی, ابراهیم, حیدر پور, عوض, فراست کیش, رسول, ماهوری, علیرضا,

Background: Measuring end tidal carbon dioxide (ETCo2) is one of the methods used for estimating arterial carbon dioxide (PaCo2) during general anesthesia. ETCo2 measurements maybe obviate the need for repeating arterial puncture for determination of arterial PaCo2. This study performed to determine the accuracy of ETCo2 levels as a measure of PaCo2 levels in patients undergoing coronary artery...

2017
Jaideep H Mehta George W Williams Brian C Harvey Navneet K Grewal Edward E George

BACKGROUND Monitoring respiratory status using end tidal CO2 (EtCO2), which reliably reflects arterial PaCO2 in intubated patients under general anesthesia, has often proven both inaccurate and inadequate when monitoring non-intubated and spontaneously breathing patients. This is particularly important in patients undergoing procedural sedation (e.g., endoscopy, colonoscopy). This can be undert...

2014
Faruk OZTURK Ismet PARLAK Sadiye YOLCU Onder TOMRUK Bulent ERDUR Rifat KILICASLAN Ali Savas MIRAN Serhat AKAY

OBJECTIVES In this study, the value of end-tidal carbon dioxide (ETCO2) levels measured by capnometry were evaluated as indicators of resuscitation effectiveness and survival in patients presenting to the emergency department with cardiopulmonary arrest. METHODS ETCO2 was measured after 2 minutes of compression or 150 compressions. ETCO2 values were measured in patients that were intubated an...

2016
Ali Taghizadieh Mahboub Pouraghaei Payman Moharamzadeh Alireza Ala Farzad Rahmani Karim Basiri Sofiani

Introduction: The routine and gold standard method to diagnose of acid - base disturbance is arterial blood gas (ABG) sampling. Capnography could be used to measure the end-tidal carbon dioxide (ETCO2) levels and ETco2 has a close correlation with the PaCo2. The aim of this study was comparison the ETco2 and arterial blood bicarbonate levels in patients with metabolic acidosis. Methods: In a de...

2017
Tomasz Darocha Sylweriusz Kosiński Anna Jarosz Paweł Podsiadło Mirosław Ziętkiewicz Tomasz Sanak Robert Gałązkowski Jacek Piątek Janusz Konstanty-Kalandyk Rafał Drwiła

BACKGROUND Severe accidental hypothermia can cause circulatory disturbances ranging from cardiac arrhythmias through circulatory shock to cardiac arrest. Severity of shock, pulmonary hypoperfusion and ventilation-perfusion mismatch are reflected by a discrepancy between measurements of CO2 levels in end-tidal air (EtCO2) and partial CO2 pressure in arterial blood (PaCO2). This disparity can pos...

2014
Henrik Sørensen Hilary P. Grocott Mads Niemann Allan Rasmussen Jens G. Hillingsø Hans J. Frederiksen Niels H. Secher

BACKGROUND As measured by near infrared spectroscopy (NIRS), cerebral oxygenation (ScO2) may be reduced by hyperventilation in the anhepatic phase of liver transplantation surgery (LTx). Conversely, the brain may be subjected to hyperperfusion during reperfusion of the grafted liver. We investigated the relationship between ScO2 and end-tidal CO2 tension (EtCO2) during the various phases of LTx...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید