نتایج جستجو برای: flowmeter
تعداد نتایج: 1129 فیلتر نتایج به سال:
was compared with blood flow simultaneously determined by an electromagnetic flowmneter around the brachial artery before, during, and after intermittent isotonic grip exercise in eight subjects. The comparison of plethysmographic flow (y axis) with simultaneously measured flowmeter flow (x axis) yielded a correlation coefficient of 0.797, a slope of 1.15 and a y intercept of 9.62. When flow wa...
Flowmeter and Calibration Facility P.J. Lefebvre Naval Underwater Systems Center, Newport, R.1. An electromagnetic flowmeter was developed to measure transient flows at a data rate of 60 Hz. The approach taken was to develop suitable electronics to replace the electronics ofa commercially available electromagnetic flowmeter normally used W. W. Durgin for steady-state operation. Use of the comme...
The wide-range ejector flowmeter is an active scavenging system applying calibrated gas removal directly to the anaesthetic circuit. The evacuation rate can be adjusted on the flowmeter under visual control using the calibration scale ranging from 200 ml X min-1 to 151 X min-1. The accuracy of the calibration was tested on three ejector flowmeters at 12 different presettings. The percentage dev...
The application of elbow flowmeter in rotary equipments is beneficial to reduce the pipeline complexity. However, intervention centrifugal acceleration will lead change metrological characteristics flowmeter. Based on analysis differential pressure formation mechanism environmental flowmeter, calculation formula flow rate measurement with rotating state derived, and fitting method discharge coe...
We determined nasal peak flow using a peak flowmeter with a face mask (PALROD peak expiratory flowmeter) and nasal airway patency with an anterior rhinomanometer (Nihon Koden MPR-1100) at a minimum time interval in the same individual. We compared the values obtained by two kinds of measurements to evaluate the usefulness of the peak flowmeter for nasal airway patency. In this study, the nasal ...
An electromagnetic flowmeter incorporated into a catheter is described. The catheter is introduced into the aorta via the femoral artery. The flow sensor is located some distance below the catheter tip and is sensitive to flow at right angles to the catheter. A crater-like elevation at one end of the transducer lumen permits funnel-like connection of the transducer to the ostium of an aortic br...
A flow meter generates flow data which contains information about each connection observed on a network from a stream of observed packets. Flow meters can be implemented in standalone measurement devices or inline on packet forwarding devices, such as routers. YAF (Yet Another Flowmeter) was created as a reference implementation of an IPFIX Metering and Exporting Process, and to provide a platf...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید