نتایج جستجو برای: ground heat exchanger
تعداد نتایج: 347966 فیلتر نتایج به سال:
BACKGROUND Ground source heat pumps is a building energy conservation technique. The underground buried pipe heat exchanging system of a ground source heat pump (GSHP) is the basis for the normal operation of an entire heat pump system. METHODS Computational-fluid-dynamics (CFD) numerical simulation software, ANSYS-FLUENT17.0 have been performed the calculations under the working conditions o...
heat exchangers are the critical components of refrigeration and liquefaction processes. selection of appropriate operational conditions for cryogenic recuperative heat exchanger and expansion valve operating in joule-thomson cooling system results in improving the performance and efficiency. in the current study, a straightforward procedure is introduced to design an efficient joule-thomson co...
in the presented research, heat transfer of a mobile electrolyte alkaline fuel cell (afc) (which the electrolyte has cooling role of system) has been considered. proper control volumes of system with specific qualification have been chosen. consequently, heat and mass transfer in control volumes have been assessed. considerations on them and contributed models lead to approve a double tube heat...
The in situ thermal conductivity of the subsurface has been measured with a novel thermal response test using heating cables inserted in a vertical ground heat exchanger. An electric current is applied along the cables to heat the borehole prior to measuring water temperature recovery at various depths inside the ground heat exchanger piping. The one-dimensional line-source equation, combined w...
Experimental investigations has been done to find out the heat transfer characteristics and friction factor of water based Al2O3 nanofluids as a coolant in brazed plate heat exchanger. Plate heat exchanger either use horizontally or vertically. The base plate of the plate heat exchanger was kept inclined at (0⁰, 30⁰ ,60⁰, 90⁰). The experimentation have been done on the two different concentrat...
Single staggered is a design development of normal wire and tube heat exchanger that wires are welded with staggered configuration on two sides. Capacity of wire and tube heat exchanger is the ability of the heat exchanger to release heat. The objective of this study is to analyse the effect of wire pitch (pw) on capacity of single staggered wire and tube heat exchanger. The research...
This paper presents the performance of a water-to-refrigerant type ground source multi-heat pump (GSHP) system installed in a school building in Korea. The evaluation of the performance has been conducted under the actual operating conditions of the GSHP system. Ten units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 ...
Ground-Coupled Heat Pumps (GCHP) are among the most efficient systems to heat and cool buildings. The high initial cost of these systems has hindered their growth in particular for residential applications. Better design methods are welcome to try to optimize the size and then the initial cost of these systems. In the field of ground heat exchanger design, the short-time behavior, which was bef...
Heat exchangers are the critical components of refrigeration and liquefaction processes. Selection of appropriate operational conditions for cryogenic recuperative heat exchanger and expansion valve operating in Joule-Thomson cooling system results in improving the performance and efficiency. In the current study, a straightforward procedure is introduced to design an efficient Joule-Thomson co...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید