نتایج جستجو برای: gyn brachytherapy phantom

تعداد نتایج: 25431  

Abdolazim Sedighi Mohammad Hadi Gholami, Ramin Jaberi Razieh Zaghian

Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...

Journal: :iranian journal of medical physics 0
seyed milad vahabi energy engineering and physics department, amirkabir university of technology, tehran, iran mojtaba shamsaei zafarghandi energy engineering and physics department, amirkabir university of technology, tehran, iran

introduction dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. three radioisotopes, namely, 125i, 103pd, and 131cs, are extensively used in this method. in this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...

ژورنال: سنجش و ایمنی پرتو 2019

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

2016
Boram Lee Sung Hwan Ahn Hyeyoung Kim Jaeman Son Jiwon Sung Youngyih Han Seung Jae Huh Jin Sung Kim Dong Wook Kim Myonggeun Yoon

This study was designed to estimate radiation-induced secondary cancer risks from high-dose-rate (HDR) brachytherapy and external radiotherapy for patients with cervical cancer based on measurements of doses absorbed by various organs. Organ doses from HDR brachytherapy and external radiotherapy were measured using glass rod dosimeters. Doses to out-of-field organs were measured at various loca...

Ali. S. Meigooni Bentolhoda Amanat, Fatemeh Lotfalizadeh, Mehdi Zehtabian, Mehrnoosh Karimipourfard, Neda Zaker Sedigheh Sina

Introduction Based on Task Group No. 43 (TG-43U1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods T...

Introduction: Long-term teletherapy program is not suitable for old and working patients and those living in areas where little access to primary health care is available. Accelerated partial breast irradiation (APBI) using high dose rate (HDR) brachytherapy is an appropriate alternative for these patients due to its limited number of fractions. The AccuBoost is a system for delivering APBI. Th...

2016
Hossein Khosravi Bijan Hashemi Faezeh Rahmani Ahmad Ebadi

PURPOSE In this work, gold nanoparticles (GNPs) were embedded in the MAGIC-f polymer gel irradiated with the 192Ir brachytherapy sources. MATERIAL AND METHODS At the first plexiglas phantom was made as the human pelvis. The GNPs were synthesized with 15 nm in diameter and 0.1 mM (0.0197 mg/ml) in concentration by using a chemical reduction method. Then, the MAGIC-f gel was synthesized. The fa...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2006
Richard Pötter Christine Haie-Meder Erik Van Limbergen Isabelle Barillot Marisol De Brabandere Johannes Dimopoulos Isabelle Dumas Beth Erickson Stefan Lang An Nulens Peter Petrow Jason Rownd Christian Kirisits

The second part of the GYN GEC ESTRO working group recommendations is focused on 3D dose-volume parameters for brachytherapy of cervical carcinoma. Methods and parameters have been developed and validated from dosimetric, imaging and clinical experience from different institutions (University of Vienna, IGR Paris, University of Leuven). Cumulative dose volume histograms (DVH) are recommended fo...

2016
Somayeh Asadi Mehdi Vaez‐zadeh Mohammad Vahidian Mahdieh Marghchouei S. Farhad Masoudi

The aim of the present Monte Carlo study is to evaluate the variation of energy deposition in healthy tissues in the human eye which is irradiated by brachytherapy sources in comparison with the resultant dose increase in the gold nanoparticle (GNP)-loaded choroidal melanoma. The effects of these nanoparticles on normal tissues are compared between 103Pd and 125I as two ophthalmic brachytherapy...

Seyed Farhad Masoudi, Somayeh Asadi, Zohreh Dehghannia Rostami

Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید