Mohammad Javad Tahmasebi Birgani Nahid Chegeni Mohammad Ali Behrooz Marziyeh Bagheri Amir Danyaei Azin Shamsi

INTRODUCTION One of the important input factors in the commissioning of the radiotherapy treatment planning systems is the phantom scatter factor (Sp) which requires the same collimator opening for all radiation fields. In this study, we have proposed an analytical method to overcome this issue. METHODS The measurements were performed using Siemens Primus Plus with photon energy 6 MV for fiel...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2006
Masanori Yamada Hideki Inakoshi Takahide Hayakawa Tomio Inoue Toshifumi Kasahara Satoshi Igarashi

To more easily estimate accurate values of collimator scatter facor, S(c), we suggest a two-component saturation model that accounts for scatter from the primary collimator and flattening filter and from the collimator jaws. This model, which assumes an exponential distribution of scatter intensity, was tested by in-air measurements using a mini-phantom for 4 MV and 10 MV X-rays of a Clinac 210...

2013
Hisayuki Miyashita Shogo Hatanaka Yukio Fujita Shimpei Hashimoto Atsushi Myojyoyama Hidetoshi Saitoh

Output factor (Scp) is one of the important factors required to calculate monitor unit (MU), and is divided into two components: phantom scatter factor (Sp) and in-air output ratio (Sc). Generally, Sc for arbitrary fields are calculated using several methods based on Sc determined by the absorbed dose measurement for several square fields. However, there are calculation errors when the treatmen...

Fariba Eyni Maryam Atarod, Mohammad Javad Tahmasebi Birgani Nahid Chegeni Seyed Mojtaba Hosseini

Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...

2016
Mukesh N. Meshram Srimanta Pramanik C.P. Ranjith Saravana K. Gopal Rishabh Dobhal

This study presents the basic dosimetric properties of photon beams of a Versa HD linear accelerator (linac), which is capable of delivering flattening filter-free (FFF) beams with a beam quality equivalent to the corresponding flattened beams based on comprehensive beam data measurement. The analyzed data included the PDDs, profiles, penumbra, out-of-field doses, surface doses, output factors,...

2015
Hiroaki Shimamoto Iori Sumida Naoya Kakimoto Keisuke Marutani Ryoko Okahata Ai Usami Tomomi Tsujimoto Shumei Murakami Souhei Furukawa Sotirios Tetradis

The presence of dental metals creates radiation dose perturbation due to scattered radiation during radiation therapy for the head and neck region. The purpose of our study was to compare the scatter doses resulting from various dental metals in the direction of the buccal mucosa among a single-field technique, three-dimensional conformal radiation therapy (3D CRT), and intensity-modulated radi...

Journal: :Medical physics 2012
S Park S Kim Y Park J Park J Kim H Kim C Choi S Ye

PURPOSE Scattered radiation from multi-leaf collimators (MLCs) is no longer negligible for calculating in-air output ratio, Sc for small and irregular fields often used in intensity-modulated radiation therapy (IMRT). An extra-focal source model for scattered radiation from MLCs, namely MLC scatter source, has been developed to improve the accuracy of the Sc calculation. METHODS A conventiona...

2017
Cong Zhao Xi Chen Luo Ouyang Jing Wang Mingwu Jin

Scatter contamination is one of the main sources of decreasing the image quality in cone-beam computed tomography (CBCT). The moving blocker method is economic and effective for scatter correction (SC), which can simultaneously estimate scatter and reconstruct the complete volume within the field of view (FOV) from a single CBCT scan. However, at the regions with large intensity transition in t...

Journal: :Medical physics 2006
J H Siewerdsen M J Daly B Bakhtiar D J Moseley S Richard H Keller D A Jaffray

X-ray scatter poses a significant limitation to image quality in cone-beam CT (CBCT), resulting in contrast reduction, image artifacts, and lack of CT number accuracy. We report the performance of a simple scatter correction method in which scatter fluence is estimated directly in each projection from pixel values near the edge of the detector behind the collimator leaves. The algorithm operate...