نتایج جستجو برای: initial corrosion

تعداد نتایج: 399340  

Journal: :Materials science & engineering. C, Materials for biological applications 2016
Emily K Brooks Stephanie Der Mark T Ehrensberger

Magnesium (Mg) and its alloys, including Mg-9%Al-1%Zn (AZ91), are biodegradable metals with potential use as temporary orthopedic implants. Invasive orthopedic procedures can provoke an inflammatory response that produces hydrogen peroxide (H2O2) and an acidic environment near the implant. This study assessed the influence of inflammation on both the corrosion and mechanical properties of AZ91....

2011
Norio Sato

Metallic materials in practical use are normally exposed to corrosion in the atmospheric and aqueous environments. Metallic corrosion is one of the problems we have often encountered in our industrialized society; hence it has been studied comprehensively since the industrial revolution in the late eighteenth century. Modern corrosion science was set off in the early twentieth century with the ...

2000
Alberto A. Sagüés Rodney G. Powers Richard Kessler

Severe corrosion of epoxy coated rebar in the substructure of 5 major marine bridges in the Florida Keys was detected after only a few years of construction. Corrosion occurred underneath the coating and was preceded by loss of adherence between the steel and the coating. Damage surveys of the bridges, which were built around 1980, were conducted from 1986 to 2000. Corrosion resulted in delamin...

Journal: :Environmental science. Processes & impacts 2014
Huifang Sun Baoyou Shi Darren A Lytle Yaohui Bai Dongsheng Wang

To understand the formation and release behavior of iron corrosion products in a drinking water distribution system, annular reactors (ARs) were used to investigate the development processes of corrosion products and biofilm community as well as the concomitant iron release behavior. Results showed that the formation and transformation of corrosion products and bacterial community are closely r...

2017
Dan Song Cheng Li Liwen Zhang Xiaolong Ma Guanghui Guo Fan Zhang Jinghua Jiang Aibin Ma

In this study, we report an effective approach, pre-solid solution (SS) treatment, to reduce the in-vitro bio-degradation rate of the hydrothermal-synthesizing coated Mg-2Zn-Mn-Ca-Ce alloy in Hanks' solution. Pre-SS treatment alters the microstructure of alloys, which benefits the corrosion resistances of the substrate itself and the formed coating as well. The micro-galvanic corrosion between ...

2008
Alberto A. Sagüés

This work is a preliminary examination of mechanistic issues on the comparative corrosion performance of regular epoxy-coated rebar (ECR) and dual polymer-zinc coated reinforcement (DCR) in simulated concrete pore solution with and without chloride ions, at polarizations from +100 mV to -1000 mV in the saturated calomel electrode (SCE) scale and exposure periods of 1 month or longer. Both mater...

2006
E A Birt L D Jones L J Nelson

The repair and rectification of corrosion damage continues to be a major factor in the life cycle costs of aircraft. The present approach to corrosion control is based on ‘Find-and-fix’. Once an area of corrosion is found, rectification is carried out as soon as possible. This often involves the blending away of corrosion damage and the re-protection of the blended area. Where the depth of corr...

2016
Dong Chen Max Yen Paul Lin Steve Groff Richard Lampo Michael McInerney Jeffrey Ryan Dong CHEN Max YEN Paul LIN Steve GROFF Richard LAMPO Michael MCINERNEY Jeffrey RYAN

An innovative sensor containing A36 carbon steel was explored for corrosion monitoring. After being soaked in an aerated 0.2 M NaCl solution, the sensor’s normalized electrical resistance (R/R0) decreased continuously with the extent of corrosion from 1 to 0.64. Meanwhile, the sensor’s normalized capacitance (C/C0) increased continuously from 1.0 to 1.42. The sensors can be attached to a struct...

Journal: :The Journal of bone and joint surgery. British volume 1994
S D Cook R L Barrack A J Clemow

We examined 108 uncemented femoral stems with modular femoral heads which had been retrieved for reasons other than loosening. There were detectable amounts of wear and corrosion in 10 of 29 (34.5%) mixed-alloy components and 7 of 79 (9%) single-alloy components after a mean implantation time of 25 months. We found no correlation between the presence or extent of corrosion or surface damage and...

Journal: :Bioelectrochemistry 2014
Jason S Lee Richard I Ray Brenda J Little Kathleen E Duncan Deniz F Aktas Athenia L Oldham Irene A Davidova Joseph M Suflita

Two coastal seawaters (Key West, FL, USA and the Persian Gulf, Bahrain, representing oligotrophic and eutrophic environments, respectively) were used to evaluate potential biodegradation and corrosion problems during exposure to alternative and conventional fuels. Uncoated carbon steel was exposed at the fuel/seawater interface and polarization resistance was monitored. Under typical marine sto...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید