نتایج جستجو برای: intramedullary rod
تعداد نتایج: 28841 فیلتر نتایج به سال:
Peri-implant fractures of the distal tibia after intramedullary nailing are rare. We present a case of a fracture of the distal tibia at the site of the distal interlocking screw. We found two cases reported in the world literature. There are no cases reported in the Spanish literature.
The authors present a rare technique of tension band plating of the anterior tibia in the setting of a nonunion stress fracture. Surgical management with an intramedullary nail is a viable and proven option for treating such injuries. However, in treating elite athletes, legitimate concerns exist regarding the surgical disruption of the extensor mechanism and the risk of anterior knee pain asso...
In intramedullary nail (IMN) surgical operations, one of the main efforts for surgeons is to find the axes of two distal holes. Two distal holes on an IMN, which are inside the intramedullary canal of a patient's femur, can only be seen in a lateral X-ray view. For the standard surgical procedure, the localization of the distal hole axes is a trial-and-error process which results in a long surg...
Managing complications after attempted hind foot and ankle arthrodesis with intramedullary nail fixation is a challenge. This situation becomes more problematic in the patient with diabetes mellitus and multiple comorbidities. Infection and subsequent osteomyelitis can be a devastating, limb threatening complication associated with these procedures. The surgeon must manage both the infectious p...
Abstract Background: Pseudoarthrosis of the tibia poses one of the most challenging treatment problems in all of orthopedics. The goal of the study was to assess the clinical outcome of intramedullary rod fixation in its treatment. Methods: The results of the management for nine patients with pseudoarthrosis of the tibia with IM rod fixation were reviewed retrospectively between 198...
OBJECTIVE To compare the biomechanical properties of a 10-hole 3.5 mm locking compression plate (LCP) with 2 proximal and 2 distal bicortical locked screws reinforced with either a Steinmann pin of 30-40% the medullary diameter or a poly-ether-ether-ketone (PEEK) rod of ∼75% the medullary diameter in a cadaveric tibia gap model. STUDY DESIGN Ex vivo study. SAMPLE POPULATION Cadaveric canine...
We report a rare complication during primary total knee arthroplasty. An intramedullary femoral guide rod was broken during insertion. The broken part jammed into the isthmus of the femur. An initial attempt to push the broken rod via the proximal femur by a guide wire to the distal femur was unsuccessful because the broken rod was lodged in the isthmus. Ultimately, the isthmus was opened using...
Biodegradable implants made from polyglycolic and polylactic acid co-polymers undergo degradation by hydrolysis which results in loss oftheir mechanical strength. The degradation of 1.5 mm polyglycolide rods (Biofix) was studied after intramedullary and subcutaneous implantation in rabbits. Two weeks after implantation there was a 73% reduction in strength of the intramedullary implants and a 6...
Metacarpal shaft fractures tend to shorten and angulate. This tendency is accentuated with the fracture of multiple metacarpals. A variety of methods for treatment have been described. The purpose of this study is to present the results of treatment in patients with multiple metacarpal shaft fractures, treated in a minimally invasive manner, with an intramedullary rod device.
We report 2 patients with congenital pseudoarthrosis of the tibia who underwent intramedullary Rush rod transfixation through the ankle joint following refracture and nonunion of vascularised fibular grafting 6 and 8 months earlier. After 9 and 5 years, both Rush rods were broken at the level of the ankle joints, while the reconstructed area was solidly united. The growth of the distal tibia in...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید