2010
Atsushi Fukuda

Kilovoltage cone beam computed tomography (CBCT) imaging may be useful in verifying patient position in stereotactic radiosurgery (SRS). To evaluate its efficacy, we investigated isocenter differences in the radiation beam and CBCT with respect to the achievable setup of a conventional frame-based SRS system. A verification phantom constructed from two plastic boards and Gafchromic-EBT film (4 ...

2016
Ivan A. Brezovich Richard A. Popple Jun Duan Sui Shen Xingen Wu Sidi Benhabib Mi Huang Rex A. Cardan

Stereotactic radiosurgery (SRS) places great demands on spatial accuracy. Steel BBs used as markers in quality assurance (QA) phantoms are clearly visible in MV and planar kV images, but artifacts compromise cone-beam CT (CBCT) isocenter localization. The purpose of this work was to develop a QA phantom for measuring with sub-mm accuracy isocenter congruence of planar kV, MV, and CBCT imaging s...

2018
Malin Kügele Anneli Edvardsson Lovisa Berg Sara Alkner Carina Andersson Ljus Sofie Ceberg

The aim of this study was to investigate potential dose reductions to the heart, left anterior descending coronary artery (LAD), and ipsilateral lung for left-sided breast cancer using visually guided deep inspiration breath-hold (DIBH) with the optical surface scanning system Catalyst™, and how these potential dosimetric benefits are affected by intrafractional motion in between breath holds. ...

2014
Matthew J. Nyflot Ning Cao Juergen Meyer Eric C. Ford

Accurate alignment of linear accelerator table rotational axis with radiation isocenter is critical for noncoplanar radiotherapy applications. The purpose of the present study is to develop a method to align the table rotation axis and the MV isocenter to submillimeter accuracy. We developed a computerized method using electronic portal imaging device (EPID) and measured alignment stability ove...

Journal: :Computer aided surgery : official journal of the International Society for Computer Aided Surgery 2000
R Liao J A Williams L Myers S Li R H Taylor C Davatzikos

OBJECTIVE Computer-assisted treatment planning for linac-based radiosurgery is still an open research problem, especially for multiple-isocenter procedures, primarily due to its high complexity and computational requirements. This paper focuses on the optimization of multiple-isocenter treatment planning for linac systems, and addresses several important issues associated with multiple isocente...

2009
Huaiqun Guan Rabih Hammoud Fang‐Fang Yin

A positioning QA procedure for Varian's 2D/2D (kV/MV) and 3D/3D (planCT/CBCT) matching was developed. The procedure was to check: (1) the coincidence of on-board imager (OBI), portal imager (PI), and cone beam CT (CBCT)'s isocenters (digital graticules) to a linac's isocenter (to a pre-specified accuracy); (2) that the positioning difference detected by 2D/2D (kV/MV) and 3D/3D(planCT/CBCT) matc...

Journal: :Radiation protection dosimetry 2016
Bharti Kataria Michael Sandborg Jonas Nilsson Althén

Automatic exposure control (AEC) in computed tomography (CT) facilitates optimisation of dose absorbed by the patient. The use of AEC requires appropriate 'patient centring' within the gantry, since positioning the patient off-centre may affect both image quality and absorbed dose. The aim of this experimental study was to measure the variation in organ and abdominal surface dose during CT exam...

2005
Zhanrong Gao Janos Szanto Lee Gerig

Electronic portal imaging devices (EPIDs) are potentially valuable tools for linear accelerator quality assurance and for measuring and analyzing geometric variations in radiation treatment delivery. Geometric analysis is more robust if referenced against an absolute position such as the isocenter (collimator axis of rotation), allowing the observer to discriminate between various setup errors ...

Journal: :The journal of breast health 2014
F Gülşen Kara Ayfer Haydaroğlu Hakan Eren Gül Kitapçıoğlu

OBJECTIVE This study aimed to minimize the radiation dose to organs other than the target tissue during adjuvant therapy applied for breast cancer, by using different planning methods. MATERIALS AND METHODS 30 women with T1-2 N1-3 M0 breast cancer were included in the study. Planning was performed using four different methods to the supraclavicular area, internal, and external tangential fiel...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2010
Hiroshi Fukuma Yuta Eguchi Shigeru Isoyama Makoto Kawano Yusuke Suzuki Takahiro Aoyama Hideki Kato

The characteristics of activation after high-energy X-rays have been generated by medical linear accelerators were measured using an ionization chamber. Radiation doses increased with rising X-ray energy, based on 10 MV, 15 MV, and 18 MVX-ray measurements. When the total irradiation dose was changed, radiation dose increased with total irradiation dose. When the collimator opened, the radiation...