نتایج جستجو برای: isodose curves
تعداد نتایج: 93941 فیلتر نتایج به سال:
introduction the use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (pdd) curves. these changes and electron beam dose distribution in the form of three-dimensional (3d) can be measured by gel dosimeters. materials and methods dosimetry was performed with and without a square shield (6×6 cm2 field). the energies were 4, 9, and 16 mev and phantom w...
BACKGROUND Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges (15°, 30°, 45°, 60°),or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge,... The new formulation is presented by the comb...
BACKGROUND Wedge filters can be used as missing tissue compensators or wedge pairs to alter the shape of isodose curves so that two beams can be angled with a small hinge angle at a target volume without creating a hotspot. AIM In this study the dosimetric properties of Varian Enhanced Dynamic Wedge (EDW) and physical wedges (PW) were analyzed and compared. MATERIALS AND METHODS Ionometric ...
a method is described whereby the isodose curves of a cobalt unit were measured, using a simple photographic technique. the method reduces the effects of experimental errors and artifacts by cross_plotting the constants of decrement liner. the method is self-calibrating, and affords a useful allernative to the more usual water phantom pro:edures, in cases when this apparatus is not available
In this work isodose curves are obtained by the use of a new dosimetric algorithm using numerical data from percentage depth dose (PDD) and the maximum absorbed dose profile, calculated by Monte Carlo in a 18 MV LINAC. The software allows reproducing the absorbed dose percentage in the whole irradiated volume quickly and with a good approximation. To validate results an 18 MV LINAC with a whole...
Introduction: The dosimetric characteristics of patch sources including 32P, 90Y, 188Re and 166Ho, which are employed for radionuclide skin therapy, have been evaluated in current study Materials and Methods: The patch sources understudy were modeled by MCNPX Monte Carlo code and corresponding depth dose distribution, transverse dose profile and isodose curves...
Introduction: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges (15°, 30°, 45°, 60°), or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge, ... The new formulation is...
An apparatus was constructed to facilitate superimposition of the beam focus radiogram upon the axial transverse tomogram, in order to guide subsequent radia tion therapy more accurately. The apparatus automatically draws six isodose curves in three colors, by plotting the relative doses of the beam focus radiogram. In addition, the isodose chart was made at the same magnification as that of th...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید