2009
Georges El Fakhri Philippe Maksud André Aurengo

The detection of scattered photons affects both image quality and accuracy of quantitation accuracy in Single Photon Emission Computed Tomography (SPECT). The aim of this work was to evaluate three scatter correction methods: Jaszczak subtraction, the triple energy window method and an artificial neural network based approach. This evaluation was performed not only in terms of contrast and spat...

Journal: :Medical physics 2008
H Thisgaard M Jensen

Auger electron emitting radionuclides in cancer therapy offer the opportunity to deliver a high radiation dose to the tumor cells with high radiotoxicity while minimizing toxicity to normal tissue. We have in this study identified the Auger emitter Sb119 as a potent nuclide for targeted radionuclide therapy based on theoretical dosimetry calculations at a subcellular scale. From these calculati...

2018
M. K. Stam E. E. Verwer J. Booij S. M. Adriaanse C. M. de Bruin T. C. de Wit

Background: Single-photon emission computed tomography (SPECT) imaging is an important diagnostic tool for the early detection of the loss of nigrostriatal dopaminergic neurons in Parkinson’s disease (PD) and similar neurodegenerative disorders. Visualization and quantification of dopamine transporter (DAT) binding in the striatum is an established diagnostic tool to detect nigrostriatal dopami...

Nazila Shahmari Payvand Taherparvar

Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...

M. Amoui, M. Hosntalab, M.R. Teimoori Sichani, Sh. Akhlaghpoor,

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

Jalil Pirayesh Islamian, Parvaneh Darkhor Samira Abbaspour

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

Journal: :iranian journal of radiation research 0
m.r. teimoori sichani department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran m. amoui department of nuclear medicine, shahid beheshti university of medical science, tehran, iran sh. akhlaghpoor noor medical imaging center, tehran, iran m. hosntalab department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

background: in this study, quantitative 32p bremsstrahlung planar and spect imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate dosimetry in clinical practice. materials and methods: ct, planar and spect bremsstrahlung images of jaszczak phantom containing a known activity of 32p were acquired. in addition, phanto...

Journal: :Hellenic journal of nuclear medicine 2014
Anna Zielinski Florian F Behrendt Frederik A Verburg Felix M Mottaghy Thomas Krohn

The aim of this study is to evaluate the impact of a high resolution (HR) image reconstruction with a voxel size of 2mm in comparison to the most routinely used standard reconstruction with 4mm voxels in patients suffering from prostate cancer having undergone (18)F-methylcholine PET/CT. Phantom studies were performed using a Jaszczak phantom and a custom made phantom containing small hot lesio...

Journal: :Radiation protection dosimetry 2010
M Sydoff H Uusijärvi S Leide-Svegborn S Mattsson

Positron emission tomography combined with computed tomography (PET/CT) is a quantitative technique suitable for diagnostics and uptake measurements. The quantitative results can be used for the purpose of the calculating absorbed dose to patients undergoing nuclear medicine investigations. Hence, the accuracy of the quantification of the activity content in organs or tissues is of great import...