نتایج جستجو برای: last menauposal period lmp

تعداد نتایج: 718678  

Journal: :Contraception 2012
Rachel K Jones Lawrence B Finer

BACKGROUND Little is known about the characteristics of second-trimester abortion patients. STUDY DESIGN Data come from a national sample of 9493 women obtaining abortions in 2008. Chi-square statistics and logistic regression were used to examine demographic characteristics of women having abortions at 13 or more weeks since last menstrual period (LMP) and women having abortions at 13-15 wee...

2018
John R Weinstein Lisa M Thompson Anaité Díaz Artiga Joe P Bryan William E Arriaga Saad B Omer John P McCracken

BACKGROUND Preterm birth is the leading cause of death among children <5 years of age. Accurate determination of prematurity is necessary to provide appropriate neonatal care and guide preventive measures. To estimate the most accurate method to identify infants at risk for adverse outcomes, we assessed the validity of two widely available methods-last menstrual period (LMP) and the New Ballard...

Journal: :Cadernos de saude publica 2015
Maria Nilza Lima Medeiros Nádia Carenina Nunes Cavalcante Fabrício José Alencar Mesquita Rosângela Lucena Fernandes Batista Vanda Maria Ferreira Simões Ricardo de Carvalho Cavalli Viviane Cunha Cardoso Heloisa Bettiol Marco Antonio Barbieri Antônio Augusto Moura da Silva

The aim of this study was to assess the validity of the last menstrual period (LMP) estimate in determining pre and post-term birth rates, in a prenatal cohort from two Brazilian cities, São Luís and Ribeirão Preto. Pregnant women with a single fetus and less than 20 weeks' gestation by obstetric ultrasonography who received prenatal care in 2010 and 2011 were included. The LMP was obtained on ...

Journal: :Paediatric and perinatal epidemiology 2008
Caroline S Hoffman Lynne C Messer Pauline Mendola David A Savitz Amy H Herring Katherine E Hartmann

Reported last menstrual period (LMP) is commonly used to estimate gestational age (GA) but may be unreliable. Ultrasound in the first trimester is generally considered a highly accurate method of pregnancy dating. The authors compared first trimester report of LMP and first trimester ultrasound for estimating GA at birth and examined whether disagreement between estimates varied by maternal and...

Journal: :American journal of epidemiology 2010
William M Callaghan Patricia M Dietz

Population-based standards for infant size for gestational age depend on accurate assessments of birth weight and gestational age; the accuracy of the latter measure has been questioned. The authors sought to explore how different methods of assigning gestational age in vital records data affect distributions of birth weight for gestational age. The 2005 US natality file was used to create 4 me...

Journal: :Journal of the College of Physicians and Surgeons--Pakistan : JCPSP 2013
Faiza Naseem Naheed Fatima Shakeela Yasmeen Saima Saleem

OBJECTIVE To determine the frequency of correct assessment by transcerebeller diameter (TCD) versus biparietal diameter (BPD) for gestational age measurement at 36 weeks of pregnancy using first day of last menstrual period (LMP) for actual period of gestation. STUDY DESIGN Quasi experimental. PLACE AND DURATION OF STUDY Department of Obstetrics and Gynaecology, Bahawal Victoria Hospital, B...

2009
Rebecca E. Rosenberg A.S.M. Nawshad U. Ahmed Saifuddin Ahmed Samir K. Saha M.A.K. Azad Chowdhury Robert E. Black Mathuram Santosham Gary L. Darmstadt

The validity of three methods (last menstrual period [LPM], Ballard and Dubowitz scores) for assessment of gestational age for premature infants in a low-resource setting was assessed, using antenatal ultrasound as the gold standard. It was hypothesized that LMP and other methods would perform similarly in determining postnatal gestational age. Concordance analysis was applied to data on 355 ne...

Journal: :Obstetrics and gynecology 1999
P A Benn J F Rodis T Beazoglou

OBJECTIVE To quantify the financial benefits of using ultrasound estimation of gestational age in maternal serum screening for Down syndrome. METHODS Maternal age-specific sensitivity and false-positive rates for Down syndrome were derived for the triple test (alpha-fetoprotein, hCG, and unconjugated estriol) using gestational age based on ultrasound dating and also time from the last menstru...

2016
Alison D. Gernand Rina Rani Paul Barkat Ullah Muhammad A. Taher Frank R. Witter Lee Wu Alain B. Labrique Keith P. West Parul Christian

BACKGROUND The best method of gestational age assessment is by ultrasound in the first trimester; however, this method is impractical in large field trials in rural areas. Our objective was to assess the validity of gestational age estimated from prospectively collected date of last menstrual period (LMP) using crown-rump length (CRL) measured in early pregnancy by ultrasound. METHODS As part...

Journal: :Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology 2009
Gayane Hovhannisyan Lorraine Chow Alexandra Schlosser Martin J Yaffe Norman F Boyd Lisa J Martin

BACKGROUND In premenopausal women, the sensitivity of screening mammography for detecting breast cancer has been reported to be greater in the follicular phase than in the luteal phase of the menstrual cycle, which may be due to differences in mammographic density. To examine this possible effect, we compared mammographic density in premenopausal women who had mammograms at different phases of ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید