نتایج جستجو برای: magic gel dosimeter

تعداد نتایج: 117344  

Journal: :Physics in medicine and biology 2001
P M Fong D C Keil M D Does J C Gore

Polymer gels whose NMR and optical properties change when irradiated offer unique advantages for measuring radiation dose distributions. To date, all acrylic polymer gel dosimeters must be manufactured, stored and irradiated in hypoxic conditions which severely limits their use and stability. A new formulation of acrylic dosimeter gel has been developed that responds well in normal atmosphere a...

2016
Hossein Masoumi Manijhe Mokhtari-Dizaji Azim Arbabi Mohsen Bakhshandeh

In this study, using methacrylic and ascorbic acid in gelatin initiated by copper (MAGIC-f) polymer gel after megavoltage energy exposure, the sensitivity of the ultrasound velocity and attenuation coefficient dose-dependent parameters was evaluated. The MAGIC-f polymer gel was irradiated under 1.25 MeV cobalt-60, ranging from 0 to 60 Gy in 2-Gy steps, and received dose uniformity and accuracy ...

Journal: :iranian journal of medical physics 0
hamid reza sadoughi m.sc. student of medical physics, medical physics dept., tehran university of medical sciences, tehran, iran mahmood allahverdi associate professor, medical physics dept., tehran university of medical sciences, and radiotherapy physics department of cancer institute, tehran, iran hasan nedaei assistant professor, radiotherapy physics dept., cancer institute, tehran, iran ramin jaberi radiotherapy physicist, radiotherapy physics dept., cancer institute, tehran, iran mahbod esfahani radiotherapy physicist, radiotherapy physics dept., cancer institute, tehran, iran alireza shirazi associated professor, medical physics dept., tehran university of medical sciences, tehran, iran

introduction: multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. in this work, we investigated mr-based magic gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. materials and methods: a heterogeneous slab phantom including bones was made....

Alireza Shirazi, Hamid Reza Sadoughi Hasan Nedaei Mahbod Esfahani Mahmood Allahverdi Ramin Jaberi

Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made....

Journal: :iranian journal of radiation research 0
n.n.a razak school of physics, university sains malaysia, 18000, pulau pinang, malaysia a.a. rahman 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia s. kandaiya 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia i.s. mustafa 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia a.a. mahmoud 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia n.z. yahaya school of distance education, university sains malaysia, 18000, pulau pinang, malaysia

background: an effective polymer gel dosimeter can be fabricated by varying the composition of its chemical components. materials and methods: the magat gel dosimeter formulations that used different compositions of methacrylic acid (maa) and gelatin were extensively investigated in the present study according to the r2–dose response and r2–dose sensitivity. the irradiation of magat gel was per...

Hasan Nedaie Hossein Hasani, Mahmood Allahverdi Mohammad Hasan Zahmatkesh Saeid Bagheri Sajad Mirzaie

Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...

Journal: :iranian journal of medical physics 0
hadis ansari mehr1 department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

introduction the use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (pdd) curves. these changes and electron beam dose distribution in the form of three-dimensional (3d) can be measured by gel dosimeters. materials and methods dosimetry was performed with and without a square shield (6×6 cm2 field). the energies were 4, 9, and 16 mev and phantom w...

Journal: :iranian journal of radiation research 0
w. parwaie department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran m. yarahmadi department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of radiotherapy, cancer institute, tehran university of medical sciences, tehran, iran m.h. zahmatkesh shahid beheshti university of medical sciences, tehran, iran a.h. barati department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran m. afkhami department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran

background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...

2014
S. M. Gafar

In this study the spectrophotometric response of the Toluidine Blue O (TBO)-gelatin gel dosimeter irradiated with gamma rays was characterized. Preparation of dyed-gelatin gel takes place in neutral medium; to give eventually gel dosimeter has a sharp absorbance peak at 635 nm that bleaches quantitatively upon irradiation and the colour change can be measured with UV-VIS spectrophotometer. The ...

Journal: :iranian journal of radiation research 0
d. shahbazi-gahrouei dr. d. shahbazi-gahrouei; dept. of medical physics, sharekord university of medical sciences, sharekord, iran.fax: +98-381-3334911

background: the compositions of ferrous sulphate, agarose and xylenol orange dye (fax) and ferrous sulphate, gelatin and xylenol orange dye (fgx) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. ionizing radiation causes oxidation of fe2+ ion to fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید