نتایج جستجو برای: magnetoelectronics
تعداد نتایج: 43 فیلتر نتایج به سال:
Highly compliant electronics, naturally conforming to human skin, represent a paradigm shift in the interplay with surroundings. Solution-processable printing technologies are yet be developed comply requirements mechanical conformability of on-skin appliances. Here, it is demonstrated that high-performance spintronic elements can printed on ultrathin 3 µm thick polymeric foils enabling mechani...
A novel fabrication method for stretchable magnetoresistive sensors is introduced, which allows the transfer of a complex microsensor systems prepared on common rigid donor substrates to prestretched elastomeric membranes in a single step. This direct transfer printing method boosts the fabrication potential of stretchable magnetoelectronics in terms of miniaturization and level of complexity, ...
High-performance giant magnetoresistive (GMR) sensorics are realized, which are printed at predefined locations on flexible circuitry. Remarkably, the printed magnetosensors remain fully operational over the complete consumer temperature range and reveal a giant magnetoresistance up to 37% and a sensitivity of 0.93 T(-1) at 130 mT. With these specifications, printed magnetoelectronics can be co...
Related Articles Room temperature deposition of alumina-doped zinc oxide on flexible substrates by direct pulsed laser recrystallization Appl. Phys. Lett. 100, 151902 (2012) Optimization of sputter deposition parameters for magnetostrictive Fe62Co19Ga19/Si(100) films J. Appl. Phys. 111, 07A939 (2012) Sign change in the organic magnetoresistance of tris(8-hydroxyquinolinato)aluminum upon anneali...
Spintronics/magnetoelectronics brought at the center of scientific research the Heusler and full-Heusler compounds, since several among them have been shown to be half-metals. In this review we present a study of the basic electronic and magnetic properties of both Heusler families; the so-called semi-Heusler alloys like NiMnSb and the full-Heusler alloys like Co2MnGe (usual full-Heuslers), Mn2...
A significant challenge for all biosensor systems is to achieve high assay sensitivity and specificity while minimizing sample preparation requirements, operational complexity, and sample-to-answer time. We have achieved multiplexed, unamplified, femtomolar detection of both DNA and proteins in complex matrices (including whole blood, serum, plasma, and milk) in minutes using as few as two reag...
Focused-ion-beam ~FIB! milling has been used to structure magnetic nanoelements from 5 nm thick films of permalloy. We have used focused 30-keV Ga ions to define small arrays (6 mm 36 mm) of wires, circles, and elongated hexagons in the size range 100–500 nm. High-sensitivity magneto-optical measurements combined with atomic force microscopy show that very high quality magnetic nanostructures c...
Research advancement in magnetoelectronics is challenged by the lack of a table-top magnetic measurement technique with the simultaneous temporal and spatial resolution necessary for characterizing magnetization dynamics in devices of interest, such as magnetic memory and spin torque oscillators. Although magneto-optical microscopy provides superb temporal resolution, its spatial resolution is ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید