نتایج جستجو برای: mathematical head phantom

تعداد نتایج: 394361  

Journal: :Physics in medicine and biology 2008
W G Whittow C J Panagamuwa R M Edwards J C Vardaxoglou

This paper presents simulated and measured phantom results for the possible effects that head worn jewellery may have on the relative levels of energy absorbed in the human head with cellular enabled mobile communication devices. The FDTD electromagnetic code used with simple and complex anatomical mathematical phantoms was used to consider the interactions of metallic jewellery, heads and repr...

2017
Sossena Wood Narayanan Krishnamurthy Tales Santini Shailesh Raval Nadim Farhat John Andy Holmes Tamer S. Ibrahim

OBJECTIVE The purpose of this study is to design an anthropomorphic heterogeneous head phantom that can be used for MRI and other electromagnetic applications. MATERIALS AND METHODS An eight compartment, physical anthropomorphic head phantom was developed from a 3T MRI dataset of a healthy male. The designed phantom was successfully built and preliminarily evaluated through an application tha...

2017
Ji Woon Yea Jae Won Park Sung Kyu Kim Dong Youn Kim Jae Gu Kim Chan Young Seo Won Hyo Jeong Man Youl Jeong Se An Oh

This study evaluated the feasibility of utilizing a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Contoured left and right head phantoms were converted from DICOM to STL format. Fused deposition modeling (FDM) was used to construct an anthropomorphic patient-specific head phantom with a 3D printer...

Ali Jomehzadeh, Alireza Amouheidari Anton Mans Ben Mijnheer Mohammad Mohammadi, Parvaneh Shokrani

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

Journal: :Perception 2011
Vilayanur S Ramachandran Beatrix Krause Laura K Case

A student volunteer was asked to stand just behind a mannequin so that the student was looking at the back of the mannequin's plastic head. The experimenter stood off to one side and used her two hands to stroke and tap the back of the student's head in perfect synchrony with the back of the mannequin's head. After 1-2 min the majority of naive subjects tested began experiencing the sensations ...

Journal: :iranian journal of medical physics 0
m.a. oghabian associate professor, physics and biomedical engineering, tehran university of medical sciences, tehran, iran. research center for science &amp; technology in medicine, imam khomeini hospital, tehran. iran. sh. mehdipour m.sc. in research center for science &amp; technology in medicine, imam khomeini hospital, tehran. iran. n. riahicalam associate professor, physics and biomedical engineering, tehran university of medical sciences, tehran, iran. research center for science &amp; technology in medicine, imam khomeini hospital, tehran. iran. b. rafie b. sc. in medical imaging center, imam khomeini hospital, tehran university of medical sciences, tehran, iran. h. ghanaati associate professor, radiology dept., medical imaging center, imam khomeini hospital, tehran university of medical sciences, tehran, iran.

introduction: one of the major causes of image non-uniformity in mri is due to the existence of  non-homogeneity in rf receive and transmit. this can be the most effective source of error in  quantitative  studies  in  mri  imaging.  part  of  this  non-homogeneity  demonstrates  the  characteristics of rf coil and part of it is due to the interaction of rf field with the material being  imaged...

B. Rafie H. Ghanaati M.A. Oghabian N. RiahicAlam Sh. Mehdipour

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

Journal: :iranian journal of radiation research 0
m.j. tahmasebi birgani medical physics department, jondi shapour university of medical sciences, ahwaz, iran m.a. behrooz medical physics department, jondi shapour university of medical sciences, ahwaz, iran h. shahbazian radiation therapy department, golestan hospital, jondi shapour university of medical science, ahwaz, iran a. shams medical physics department, jondi shapour university of medical sciences, ahwaz, iran

background: attenuation coefficient (μ) plays an important role in calculations of treatment planning systems, as well as determination of dose distributions in external beam therapy, dosimetry, protection, phantom materials and industry. so, its exact measurement or calculation is very important. the aim of this study was to evaluate the μ in different points in the water phantom analytically ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید