A rule-based, digital, closedloop controller that incorporates “fuzzy” logic has been designed and implemented for the control of power on the 5-MWt Massachusetts Institute of Technology (MIT) Research Reactor under both steady-state and transient conditions. Based on this experience and having designed several other controllers for the same purpose, a comparison is made of the rule-based and a...