نتایج جستجو برای: ocular response analyser

تعداد نتایج: 1032425  

Journal: :journal of current ophthalmology 0
هادی استادی مقدم hadi ostadimoghaddam محمدرضا صداقت mohammad reza sedaghat سیدحسین حسینی یزدی seyyed hosein hoseini yazdi حامد نیازمند hamed niyazmand

purpose : to investigate the correlation between corneal biomechanical properties and tomographic parameters of pentacam methods : corneal biomechanical properties and tomographic results of 36 normal subjects were measured by ocular response analyzer (ora) and pentacam and the correlation between these two measurements were analyzed with pearson correlation test with spss version16. results : ...

2015
Joanna Wasielica-Poslednik Christina Butsch Christina Lampe Heike Elflein Julia Lamparter Veronika Weyer Susanne Pitz Sanjoy Bhattacharya

AIMS To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA). METHODS MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and retrospectively analyzed in...

2017
Melissa L. Murphy Olya Pokrovskaya Marie Galligan Colm O’Brien

BACKGROUND To compare corneal hysteresis (CH) measurements between patients with glaucoma, ocular hypertension (OHT) and glaucoma-like optic discs (GLD)- defined as a cup to disc ratio greater than or equal to 0.6 with normal intraocular pressure (IOP) and visual fields. The secondary aim was to investigate whether corneal resistance factor (CRF) and central corneal thickness (CCT) differ betwe...

2004
B Wimpissinger H Resch F Berisha G Weigert L Schmetterer K Polak

Aim: To investigate a potential difference in ocular vascular reactivity during carbogen breathing in optic nerve head, choroid, and retina between healthy smokers and nonsmokers. Methods: 25 (13 smokers and 12 non-smokers) healthy male volunteers participated in this observer masked, two cohort study. During inhalation of carbogen (5% CO2 and 95% O2) over 10 minutes measurements were taken usi...

Journal: :The British journal of ophthalmology 2004
B Wimpissinger H Resch F Berisha G Weigert L Schmetterer K Polak

AIM To investigate a potential difference in ocular vascular reactivity during carbogen breathing in optic nerve head, choroid, and retina between healthy smokers and non-smokers. METHODS 25 (13 smokers and 12 non-smokers) healthy male volunteers participated in this observer masked, two cohort study. During inhalation of carbogen (5% CO(2) and 95% O(2)) over 10 minutes measurements were take...

Journal: :Maedica 2015
Dana Dascalescu Catalina Corbu Mihaela Constantin Miruna Cristea Catalina Ionescu Miruna Cioboata Liliana Voinea

OBJECTIVES To investigate the relationship between corneal biomechanical changes and glaucoma severity in primary open angle glaucoma patients. DESIGN Correlation study. MATERIALS AND METHODS Our study included 70 glaucomatous eyes; they were divided in groups using Glaucoma Staging System Based on Humphrey Visual Field. Ocular Response Analyzer (ORA) was used in order to determine corneal ...

Journal: :Journal of Current Glaucoma Practice 2012

Journal: :journal of current ophthalmology 0
محمد ریاضی اصفهانی mohammad riazi esfahani ابراهیم جعفرزاده پور ebrahim jafarzadehpur حسن هاشمی hassan hashemi الینا غفاری elina ghaffari

purpose : to evaluate corneal visco-elasticity and intraocular pressure (iop) changes measured by an ocular response analyzer (ora) after scleral buckling methods : fifty-six eyes with history of scleral buckling surgery three months ago were included in the study. corneal hysteresis (ch), corneal resistance factor (crf), corneal-compensated iop (iopcc) and goldmann-correlated iop (iopg) were m...

2014
Alex Horsley Kenneth Macleod Ruchi Gupta Nick Goddard Nicholas Bell

BACKGROUND The Innocor device contains a highly sensitive photoacoustic gas analyser that has been used to perform multiple breath washout (MBW) measurements using very low concentrations of the tracer gas SF6. Use in smaller subjects has been restricted by the requirement for a gas analyser response time of <100 ms, in order to ensure accurate estimation of lung volumes at rapid ventilation ra...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید