نتایج جستجو برای: omi

تعداد نتایج: 1157  

2007
D. Balis M. Kroon M. E. Koukouli E. J. Brinksma G. Labow J. P. Veefkind R. D. McPeters

[1] In this paper we present validation results of the total ozone column data products of the Ozone Monitoring Instrument (OMI) on board the NASA EOS-AURA satellite through comparisons with ground-based observations by Dobson and Brewer spectrophotometer instruments. Quality-controlled and archived total ozone column data from these ground-based instruments located at stations worldwide have b...

2008
M. Kroon M. R. Dobber R. Dirksen J. P. Veefkind G. H. J. van den Oord P. F. Levelt

[1] Verification of the geolocation assigned to individual ground pixels as measured by the Ozone Monitoring Instrument (OMI) aboard the NASA EOS-Aura satellite was performed by comparing geophysical Earth surface details as observed in OMI false color images with the high-resolution continental outline vector map as provided by the Interactive Data Language (IDL) software tool from ITT Visual ...

2016
Vilmos Csizmadia Paul Hales Christopher Tsu Jingya Ma Jiejin Chen Pooja Shah Paul Fleming Joseph J. Senn Vivek J. Kadambi Larry Dick Francis S. Wolenski

The proteasome inhibitor bortezomib is associated with the development of peripheral neuropathy in patients, but the mechanism by which bortezomib can induce peripheral neuropathy is not fully understood. One study suggested that off-target inhibition of proteases other than the proteasome, particularly HtraA2/Omi, may be the underlying mechanism of the neuropathy. The same study also concluded...

Journal: :Cancer research 2013
Alex J Walsh Rebecca S Cook H Charles Manning Donna J Hicks Alec Lafontant Carlos L Arteaga Melissa C Skala

Abnormal cellular metabolism is a hallmark of cancer, yet there is an absence of quantitative methods to dynamically image this powerful cellular function. Optical metabolic imaging (OMI) is a noninvasive, high-resolution, quantitative tool for monitoring cellular metabolism. OMI probes the fluorescence intensities and lifetimes of the autofluorescent metabolic coenzymes reduced NADH and flavin...

2007
M. Kroon D. Balis D. Ionov M. Sneep L. Curier A. Tanskanen C. Zehner J. Carpay

In this paper we report on the progress achieved within the framework of the joint ESA KNMI NIVR Calibration and Validation Announcement of Opportunity for the Ozone Monitoring Instrument aboard the NASA EOS Aura satellite. This OMI AO effort has rendered a wealth of validation results and scientific insights. Herein this contribution only a selection of the validation results is presented. OZO...

2016
Dan Liu Xin Liu Ye Wu Wen Wang Xinliang Ma Huirong Liu Kotb Abdelmohsen

HtrA serine peptidase 2 (HtrA2), also named Omi, is a pro-apoptotic protein that exhibits dramatic changes in expression levels in a variety of disorders, including ischemia/reperfusion injury, cancer, and neurodegeneration. In our study, Omi/HtrA2 protein levels were high in the heart, brain, kidney and liver, with elevated heart/brain expression in aging mice. A similar expression pattern was...

2018
Jae Hyun Park Jong-Moon Chae R. Curtis Bay Mi-Jung Kim Keun-Young Lee Na-Young Chang

Objective The purpose of this study was to investigate factors influencing the success rate of orthodontic microimplants (OMIs) using panoramic radiographs (PRs). Methods We examined 160 OMIs inserted bilaterally in the maxillary buccal alveolar bone between the second premolars and first molars of 80 patients (51 women, 29 men; mean age, 18.0 ± 6.1 years) undergoing treatment for malocclusio...

2006
Dimitris Balis Ellen Brinksma Mark Kroon Vassilis Amiridis Christos Zerefos

Near-to-real time as well as “archive quality” Brewer total ozone observations, which are performed with well maintained and calibrated instruments over the Northern Hemisphere have been used for the validation of the total ozone column product of the Ozone Monitoring Instrument (OMI) aboard the NASA EOS-Aura satellite. During the commissioning phase of OMI, the near-to-real time ground-based d...

2008
Dylan B. Millet Daniel J. Jacob K. Folkert Boersma Tzung-May Fu Thomas P. Kurosu Kelly Chance Colette L. Heald Alex Guenther

[1] Space-borne formaldehyde (HCHO) column measurements from the Ozone Monitoring Instrument (OMI), with 13 24 km nadir footprint and daily global coverage, provide new constraints on the spatial distribution of biogenic isoprene emission from North America. OMI HCHO columns for June-August 2006 are consistent with measurements from the earlier GOME satellite sensor (1996–2001) but OMI is 2–14%...

2014

(1) An important point is the large bias (30-50%) between OMI (KNMI DOMINO v2.0) and SCIAMACHY nadir (KNMI-BIRA TM4NO2A v2.3) retrievals, especially if both data sets are photochemically converted. It is puzzling me because Dirksen et al. (2011) and Hendrick et al. (2012) found a good agreement between OMI, SCIAMACHY nadir and groundbased observations, suggesting the absence of such a large bia...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید