نتایج جستجو برای: operative gamma camera

تعداد نتایج: 269893  

Journal: :Proceedings of the Royal Society of Medicine 1972

A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...

Journal: :iranian journal of nuclear medicine 0
alireza sadremomtaz department of physics, faculty of science, university of guilan, rasht, iran zeinab telikani department of physics, faculty of science, university of guilan, rasht, iran

introduction: image quality and accuracy of in vivo activity quantification in spect are affected by collimator penetration and scatter components, especially in high energy imaging. these phenomena highly depend on the collimator characteristic and photon energy. the presence of penetrated and scattered photons from collimator in spect images degrades spatial resolution, contrast and image qua...

Journal: :Annals of nuclear medicine 2001
T Inoue N Oriuchi K Koyama A Ichikawa K Tomiyoshi N Sato K Matsubara H Suzuki J Aoki K Endo

AIM A comparative study of the images obtained with a dual-head coincidence gamma camera with thick NaI crystals (19 mm), a dedicated PET camera with BGO crystals and a conventional gamma camera with thin NaI crystals (9.5 mm) was conducted to clarify the clinical feasibility of a dual-head coincidence gamma camera with thick NaI crystals. METHODS FDG images of 27 patients with malignant tumo...

ژورنال: سنجش و ایمنی پرتو 2020

Radioactive materials used in nuclear medicine are the radioisotopes or drugs that are identified with radioisotopes. A radiopharmaceutical transfusion is one of diagnostic methods and a radiation value approved should be measured. The nuclear medicine images of diagnostic methods can be made by a gamma camera (γ-camera). In this article, we used MCNPX2.4 for internal dosimetry assessment when ...

Introduction: Substantive amount of work has been done in modeling and analyzing the scintillation camera system processes including positioning and image formation. The goal of this work is to develop a framework for analyzing performance of nonlinear positioning methods upon construction of a mathematical model of the system. In this study, the photodetector array counts are ...

Journal: :IEEE Transactions on Nuclear Science 1976

Journal: :RADIOISOTOPES 2001

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید