نتایج جستجو برای: oscillometry

تعداد نتایج: 732  

2017
Amir M. Benmira Antonia Perez-Martin Sarah Coudray Iris Schuster Isabelle Aichoun Jérémy Laurent Fethi Bereski-Reguig Michel Dauzat

BACKGROUND Noninvasive blood pressure (BP) measurement is essential for the study of human physiology but automatic oscillometric devices only estimate SBP and DBP using various, undisclosed algorithms, precluding standardization and interchangeability. We propose a novel approach by tracking, during pneumatic cuff deflation, the time interval from the foot to the apex of the systolic peak of t...

Journal: :middle east journal of digestive diseases 0
esmaeil eidani seyedjalal hashemi hanieh raji mehdi hosainiaskarabadi

background the relationship between gastroesophageal reflux (gerd) and airway diseases is still a matter of debate. oscillometry is an objective, independent tool for the evaluation of airway resistance. the main purpose of this study is to comparespirometry and oscillometry results before and after treatment by a proton pump inhibitor (ppi) in a group of gerd patients who have no respiratory s...

2013
Igor N Posokhov

This review describes issues for the estimation of pulse wave velocity (PWV) under ambulatory conditions using oscillometric systems. The difference between the principles of measuring the PWV by the standard method and by oscillometry is shown, and information on device validation studies is summarized. It was concluded that currently oscillometry is a method that is very convenient to use in ...

2013
Bill Diong Kshitiz singh rogelio Menendez

License. The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Ltd, provided the work is properly attributed. Permissions beyond the scope of the License are administered by Dove Medical Press Ltd. Information on how to request permission may be found at:...

Journal: :Thorax 2007
Martin K Johnson Malcolm Birch Roger Carter John Kinsella Robin D Stevenson

BACKGROUND Within-breath reactance from forced oscillometry estimates resistance via its inspiratory component (X(rs,insp)) and flow limitation via its expiratory component (X(rs,exp)). AIM To assess whether reactance can detect recovery from an exacerbation of chronic obstructive pulmonary disease (COPD). METHOD 39 subjects with a COPD exacerbation were assessed on three occasions over 6 w...

Journal: :Journal of allergy and clinical Immunology 2023

BackgroundThe effort-independent tidal breathing test used by oscillometry presents a viable alternative for following up patients whose condition is stable while they are receiving biologic therapy.ObjectiveWe aimed to determine intrasession and intersession repeatability values airwave (AOS) spirometry in who were already taking benralizumab.MethodsIn all, 21 with severe eosinophilic asthma a...

2011
Junichi Ohishi Hajime Kurosawa Hiromasa Ogawa Toshiya Irokawa Wataru Hida Masahiro Kohzuki

BACKGROUND The impulse oscillometry is increasingly used for assessing the oscillatory mechanics of the respiratory system. The within-breath behaviour of the oscillatory mechanics in chronic obstructive pulmonary disease (COPD) is a well-known physiological feature. The purpose of this study was to develop a new approach for assessing this feature using impulse oscillometry. METHODS The osci...

Journal: :Respiratory care 2016
Maíra S de Assumpção Renata M Gonçalves Renata Martins Tatiana G Bobbio Camila Is Schivinski

BACKGROUND The impulse oscillometry system is a noninvasive method of evaluating respiratory mechanics that is being increasingly used in the pediatric population. To date, no reference equations have been developed for healthy Brazilian children and adolescents. The purpose of the study was to determine the reference equations for impulse oscillometry system parameters in healthy children and ...

2013
Linnea Jarenbäck Jaro Ankerst Leif Bjermer Ellen Tufvesson

Classification of COPD into different GOLD stages is based on forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) but has shown to be of limited value. The aim of the study was to relate spirometry values to more advanced measures of lung function in COPD patients compared to healthy smokers. The lung function of 65 COPD patients and 34 healthy smokers was investigated using ...

2017
Antonio Molino Francesca Simioli Anna Agnese Stanziola Mauro Mormile Maria Martino Maria D’Amato

BACKGROUND Small airways are considered the major site of airflow limitation in COPD. Impulse oscillometry (IOS) is a forced oscillation technique, which provides passive measurement of lung mechanics. It can differentiate small airway from large airway obstruction and is more sensitive than spirometry for peripheral airway disease. In this study the efficacy of the combination of Indacaterol/G...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید