نتایج جستجو برای: pagat polymer

تعداد نتایج: 93037  

Journal: :iranian journal of medical physics 0
bakhtiar azadbakht instructor, medical radiation engineering dept, faculty of engineering, borujerd islamic azad university, borujerd, iran. *, mohammad hassan zahmatkesh associate professor, shahid beheshti university, evin, tehran, iran kamal haddad associate professor, nuclear engineering dept, faculty of engineering, shiraz university, shiraz, iran. saeid bagheri m.sc. in medical physics, shahid beheshti university, tehran, iran

introduction: the pagat polymer gel dosimeter melts at 30 ˚c and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. to increase the stability of the pagat gel, different amounts of agarose were added to the pagat gel composition and the pagata gel was manufactured. material and methods: the pagata gel vials were irradiated using a co-60 ma...

2010
T. Allahverdi Pourfallah M. Allahverdi N. Riyahi Alam M. R. Ay M. H. Zahmatkesh

*Corresponding author: Dr. Tayyeb Allahverdi Pourfallah, Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran. Fax: +98 21 88973653 E-mail: [email protected] Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equi...

2012
Tayeb Allahverdi Pourfallah Mahmoud Allahverdi Mohammad Hasan Zahmatkesh

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

Mahmoud Allahverdi Mohammad Hasan Zahmatkesh Tayeb Allahverdi Pourfallah,

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

Journal: :iranian journal of radiation research 0
t. allahverdi pourfallah department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran n. riyahi alam department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m.r. ay research center for science and technology in medicine, tehran university of medical sciences, tehran, iran m.h. zahmatkesh novin medical radiation institute, tehran, iran

background: polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. mri polymer gel dosimeters are tissue equivalent and can act as a phantom material. in this study the obtained isodose maps with pagat polymer gel dosimeter were compared to those calculated with egsnrs for singleshot irradiations of 8 and 18 mm collimators of gamma ...

2014
Parvin Mohammadyari Mehdi Zehtabian Sedigheh Sina Ali Reza Tavasoli Reza Faghihi

Currently, the use of blood irradiation for inactivating pathogenic microbes in infected blood products and preventing graft-versus-host disease (GVHD) in immune suppressed patients is greater than ever before. In these systems, dose distribution and uniformity are two important concepts that should be checked. In this study, dosimetry of the gamma chamber blood irradiator model Gammacell 3000 ...

M. Allahverdi, M.H. Zahmatkesh, M.R. Ay, N. Riyahi Alam, T. Allahverdi Pourfallah,

Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study the obtained isodose maps with PAGAT polymer gel dosimeter were compared to those calculated with EGSnrs for singleshot irradiations of 8 and 18 mm collimators of...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید